Spectra 1728/EX & 1738/EX - 21 - Programming Guide
Bold = Default Setting
PGM PROGRAMMING
The PGM Deactivation event can be used as another activation event if the PGM Timer (section [554]) is programmed with a
value other than 000. The PRT1 module uses the same PGM events as the Spectra control panel, please refer to
“Programmable Outputs” on page 7
Section # Decimal Value (000-255) Description Default Value
[554] ___/___/___ seconds (000 = fo llow de activation eve nt) PG M1 TIMER 5 sec.
Section # Event Group # Sub-Group # Partition #
[555] PGM1 Acti vation Event ___/___ ___/_ __ ___/___
[556] PGM1 Deactivation Event ___/___ ___/___ ___/___
CLOCK PROGRAMMING
For example, to enter the date March 26, 2000 you would enter 20 (century), 00 (year), 03 (month), and 26 (day).
Section # Val ue
[557] Year ___/___/___/___ Month ___/___ Day ___/___
SECTION [553]: SERIAL AND PARALLEL PORT SETUP OPTIONS
Option
OFF ON
[1]
Seri al Port N Disabled N Enabled
[2]&[3]
N see table
N see table
N see table
N see table
[4]
Parallel Port N Disabled N Enabled
[5]
Off-l ine Status Ig no re d (paral lel por t onl y) N Disabled N Enabled
[6]
Paper Empty Status Ignored (parallel port only) N Disabled N Enabled
[7]
Printer Fault Status Ignored (parallel port only) N Disabled N Enabled
[8]
Printer Busy Status Ignored (parallel port only) N Disabled N Enabled
Baud Rate Settin gs
[2] [3] APR-PRT1 APR3-PRT1
OFF OFF 1200 baud (default) 2400 baud (default)
ON OFF 2400 baud 9600 baud
OFF ON 9600 baud 19200 baud
ON ON 19200 baud 57600 baud