Spectra 1728/EX & 1738/EX - 23 - Programming Guide
WIRELESS BUS MODULES
Only o ne OM N-RC V3 (Omnia) can be connected to each Spectra con trol panel.
ZONE ASSIGNMENT
The ser ial number can be located on th e inside of the transmitter or you can use the Serial Number Display feature (see
page 23).
Also, refer to “ Zone Recognition Table” on page 4.
Section # Serial #
[601] ___/___/___/___/___/___= EXPA NSION IN PU T 1
[602] ___/___/___/___/___/___= EXPA NSION IN PU T 2
[603] ___/___/___/___/___/___= EXPA NSION IN PU T 3
[604] ___/___/___/___/___/___= EXPA NSION IN PU T 4
[605] ___/___/___/___/___/___= EXPA NSION IN PU T 5
[606] ___/___/___/___/___/___= EXPA NSION IN PU T 6
[607] ___/___/___/___/___/___= EXPA NSION IN PU T 7
[608] ___/___/___/___/___/___= EXPA NSION IN PU T 8
Bold = Default Setting
* Section [610] option [1] Wireless Transmitter Check-in Supervision must be enabled (ON) for UL installations.
Section # Decimal Value (000-255) Description Default Value
[615] ___/___/___ (001-008 = expansion inputs 1-8) ON-BOARD TA MP ER ZO NE A SSIGN. 000
PGM ACTIVATION/DEACTIVATION
PGM1 is always enabled and is activated through the Omnia Remote Control (OMN-RCT1). Remote control button C
controls PGM 1. A second 5A PGM rel ay output (PGM 2) is availa ble as an opti on . Remote control button D controls PGM2
(optional). Press the appropriate button to activate the PGM that it controls. Section [610] options [6] and [7] determine how
the respective PGM will deactivate. If the option is OFF, the activated PGM will automatically deactivate after 2 seconds. If
the option is ON, each activated PGM can be deactivated only by pressing the appropriate button on an Omnia Remote
Control that controls a PGM. For a diagram of the Omnia Remote Control, refer to “Button Options” on page 24.
SERIAL NUMBER DISPLAY
Section # Description
[630] Press the tamper switch of the Omnia Wireless Transmitter. The keypad will emit a confirmation beep. On
LED keypads, press the [ENTER] key to view the digits one at a time. On LCD keypads, the first 3 digits of
the serial number will appear. Press the [ENTER] key 3 times to view the next 3 digits. Continue activating
the desired transmitters or press [CLEAR] to exit.
SECTION [610]: GENERAL OPTIONS
Option
OFF ON
[1] Wireless Transmitter Check-in Supervision* N Disabled N Enabled
[2] Check-in Supervision Base Time Setting (must
be same as the transmitter’s jumper setting)
N Hours N Minutes
[3] & [4] Future Use N N/A N N/A
[5] Check-in Supervision Time Value (must be
same as the transmitter’s jumper setting)
N 12 N 6
[6] PGM1 Deactivation N 2 second Timer N Manually
[7] PGM2 Deactivation N 2 second Timer N Manually
[8] Future Use N N/A N N/A