Spectra 1728/EX & 1738/EX - 22 - Programming Guide
VOICE-ASSISTED ARM/DISARM BUS MODULE V2.0
Due to InTouch s Auto-recognition fe ature, it can be used wi th either the Spectra ( V2.0 or hig h er) , D igi plex or D igi plexNE
control panel . When connected to th e bu s, InTo u ch automatically de tects which control panel it is connecte d to and adjusts its
internal communication parameters to function accordingly. Only one InTouch can be connected to each Spectra control
panel.
APR3-ADM2 can also be programmed using the WinLoad Software. Refer to the WinLoad Online Help for more information.
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and Digiplex. Modules with the
APR3- prefix are compatible with Spectra (versions 2.0 and higher), Digiplex and DigiplexNE.
Section # Decimal Value (000-255) Description Default Value
[575] ___/___/___ rings (000 = disabled) NUMBER OF RINGS 8 ri ngs
[576] ___/___/___ seconds (010-255, 00 0 = disabled) ANSW ERING MACHINE OVERRIDE 000
[577] ___/___/___ seconds/minutes (000 = disabled) PG M TIMER 005
Bold = Default Setting
SECTION [578]: GENERAL OPTIONS
Option
OFF ON
[1]
Stan d- al on e Code Length N 6-digits N 4-digits
[2]
Partitioned System N Disabled N Enabled
[3]
PGM Output N Disabled N Enabled
[4]
PGM Ti me in N Seconds N Minutes
[5]
Future Use N N/A N N/A
[6]
Future Use N N/A N N/A
[7]
Future Use N N/A N N/A
[8]
Future Use N N/A N N/A