Spectra 1728/EX & 1738/EX - 26 - Programming Guide
ZONE EXPANSION BUS MODULES
Only on e SPC /APR3- ZX4 or one SPC/APR3 -ZX8 can be connected to ea ch Spe ctr a control panel . The follo wing secti ons
are for SPC-ZX4 version 1.0, APR3-ZX4 version 1.0, SPC-ZX8 version 1.0 and APR3-ZX8 version 2.0.
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and Digiplex. Modules with the
APR3- prefix are compatible with Spectra (versions 2.0 and higher), Digiplex and DigiplexNE.
Bold = Default Setting
PGM PROGRAMMING (SPC-ZX8 an d APR3-ZX8 Only)
The PGM will only activate or deactivate 100mS after the selected event occurs. The PGM Deactivation event can be used
as another activation event if the PGM Timer (section [655]) is programmed with a value other than 000. The system will
ignore the PGM if it has been programmed to follow the Global PGM (option [3] in section [650]). Only PGM events from the
table below can be used.
Section # Decimal Value (000-255) Description Default Value
[655] ___/___/___ seconds (000 = follow deactivation event) PG M1 TIMER 5 sec.
Section # Event Group # Sub-Group # Partition #
[656] PGM 1 Acti vatio n Event ___/___ ___/___ ___/___
[657] PGM 1 Deactivation Event ___/___ ___/___ ___/___
UL Note: The Zone Expansion Bus Modules are not UL listed.
SECTION [650]: Options
Option
OFF ON
[1]
EOL (end-of-l ine) Resistors for hardwire modules N No EOL N Use EOL Resistors
[2]
Zone Expansion Module Tamper Recognition N Disabled N Z1 becomes tamper input
[3]
PGM 1 on SPC/APR 3- ZX8 follows Globa l PGM
pr og rammed in sections [124] & [125]
N Disabled N Enabled
[4]-[8]
Future Use N N/A N N/A
SECTION [651]: ZONE ASSIGNMENT
Op tion See Zon e Recognition Table” on page 4. OFF ON
[1] Input Z1 =Expansion Input 1 N Disabled N Enabled
[2] Input Z2 =Expansion Input 2 N Disabled N Enabled
[3] Input Z3 =Expansion Input 3 N Disabled N Enabled
[4] Input Z4 =Expansion Input 4 N Disabled N Enabled
[5] Input Z5 (SP C/AP R3-ZX8 only) =Expansion Input 5 N Disabled N Enabled
[6] Input Z6 (SP C/AP R3-ZX8 only) =Expansion Input 6 N Disabled N Enabled
[7] Input Z7 (SP C/AP R3-ZX8 only) =Expansion Input 7 N Disabled N Enabled
[8] Input Z8 (SPC/AP R3-ZX8 only) =Expansion Input 8 N Disabled N Enabled
Event Group # Sub-Group # Partition #
For SPC-ZX8:
60 = Hardwire Zone Opened
61 = Hardwire Z one Closed
62 = Hardwire Tamper Opened
63 = Hardwire Tamper Closed
Fo r APR3-ZX8:
60 = Hardwire Zone/Hardwire Tamper Opened
61 = Hardwire Zone/Hardwire Tamper Closed
01 = Expansion Input 1 - Section [651] - [1]
02 = Expansion Input 2 - Section [651] - [2]
03 = Expansion Input 3 - Section [651] - [3]
04 = Expansion Input 4 - Section [651] - [4]
05 = Expansion Input 5 - Section [651] - [5]
06 = Expansion Input 6 - Section [651] - [6]
07 = Expansion Input 7 - Section [651] - [7]
08 = Expansion Input 8 - Section [651] - [8]
99 = Any zone expansion bus module input
Not used; enter 00