Speed Queen Gas Dryer - User Manual

Speed Queen Gas Dryer
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
CONNECT
DRYER TO
EXHAUST
SYSTEM
Secure all joints with clamps or duct
tape. DO NOT use sheet metal
screws or other fastening means
which extend into the duct to attach
exhaust pipe joints. They could
catch lint and reduce the efficiency
of the exhaust system.
IMPORTANT: Keep exhaust duct
as short as possible.
Be sure old ducts are clean before
installing your new dryer.
To prevent backdraft when dryer is
not in operation, outer end of
exhaust pipe must have a weather
hood with hinged dampers (obtain
locally).
Weather hood should be installed
at least 12" (30.5 cm) above the
ground. Higher clearances may be
necessary in areas where heavy
snowfall can occur.
No extra system length
consideration is necessary when
exhausting through the roof. Use
MAXIMUM EXHAUST LENGTH
table to calculate system length.
Use a roof cap that provides air
flow equal to weather hood.
Exhaust Directions
Dryer can be exhausted to the
outdoors through the back, right, or
bottom of the dryer. Gas dryers
cannot be vented out the left
side because of the burner
housing.
Dryer is shipped from factory ready
for rear exhaust. No kits required.
To exhaust dryer through sides or
bottom, install a DK1 Sales
Accessory (Directional Exhaust Kit
528P3). Available as optional
equipment at extra cost.
CONNECT GAS
SUPPLY
Installation
Instructions
Gas Dryer
Keep instructions for future
reference. Be sure manual
stays with dryer.
3
2
Exhaust System Materials
Exhaust duct must be four inches
(10.2 cm) in diameter without
obstructions. Rigid metal duct is
recommended. Non-combustible
semirigid flexible metal duct is
acceptable.
DO NOT use plastic pipe, foil pipe,
or flexible plastic pipe, because it
contributes to poor drying
performance and collects lint, which
can lead to a fire hazard. To identify
flexible foil or plastic duct, pinch the
coils of the duct between your
fingers. If the coils can be brought
together, do not use the duct.
Do Not Use
Use
Rigid Metal Semirigid Metal
Flexible Foil Plastic
4" (10.16 cm)
4" (10.16 cm)
Recommended Weather Hood
2-1/2" (6.35 cm)
Recommended
for Short Runs Only
POSITION AND
LEVEL DRYER
Place dryer in position, adjust all
legs (4) until dryer is level side to
side and front to back.
5
REMOVE PARTS
AND CLEAN
DRYER DRUM
Wipe drum with clean rag and soap
diluted in warm water to remove any
oil used in manufacturing. Make a
paste of laundry detergent and clean
drum if necessary.
1
Questions?
See Owners Manual or
call Consumer Affairs
Department 1-800-843-0304
Optional Kits
Kits are available at extra cost through
your dealer or the factory at
1-800-843-0304.
Directional Exhaust Kit
DK1 Sales Accessory (Directional
Exhaust Kit #528P3).
Flexible Metal Vent Kit
Exhausting the dryer in hard-to-reach
locations can be accomplished by
installing Kit # 521P3.
Manufactured (Mobile) Home
Installation Kit
Manufactured home anchor Kit
#526P3.
Propane Gas Conversion Kit
LPK1 Sales Accessory (L.P./Propane
Kit # 649P3).
Test for Gas
Leaks
After final gas
connection is made,
turn on manual gas
valve and test all connections in gas
supply piping for gas leaks. Leak
testing of the appliance shall be
conducted according to the
manufacturer’s instructions.
1. Place soap suds on connections.
2. If bubbles appear, a leak is
present. Shut off gas supply
valve.
3. Tighten joint if leak is at factory
fitting.
If leak is not at factory fitting,
unscrew, apply more joint
compound, and tighten to
correct leak.
4. Retest connection for leak after
tightening or adding joint
compound.
Retest any connections that
were disturbed.
Altitude
Ft (M)
Orifice
Size #
Part
number
3000 (915) 43 503778
6000 (1830) 44 58719
8000 (2440) 45 503779
9000 (2740) 46 503780
10000(3050) 47 503781
For proper operation at
altitudes above 2,500 feet
The natural gas valve spud orifice
size must be reduced to ensure
complete combustion. See table.
Connect gas supply to dryer using a new stainless steel flexible connector
or hard pipe (check local codes) according to illustration. Test for leaks and
check burner flame after gas supply is connected. See
Checking Burner
Flame
section on next page.
Dryer must be connected to type of gas as shown on nameplate located
in the door recess.
Use pipe joint compound insoluble on LP (propane) Gas, or Teflon tape,
on all pipe threads.
Purge air and sediment from gas supply line before connecting it to the
dryer. Before tightening the connection, purge remaining air from gas line
to dryer until odor of gas is detected. This step is required to prevent gas
valve contamination.
4
CONNECT
POWER CORD
TO
ELECTRICITY
See
Installation Requirements
section. Plug dryer into
3-prong grounded outlet only.
You'll Need a Few Things Before You Begin
L.P./Propane
DO NOT connect dryer to L.P./
Propane gas service without
converting the gas valve. An LPK1
Sales Accessory L.P./Propane Gas
Conversion Kit 649P3 must be
installed.
Duct Tape
Wrench
Screw
Drivers
Level
Teflon Tape or
Joint Compound
Stainless Steel
or Hard Pipe
Gas Connector
To reverse the direction that the
door opens, see the Owner’s
Manual.
Maximum Exhaust Length
Rigid Metal Duct
Number of
90º Elbows
Weather Hood
4-inch Opening
Weather Hood
2½-inch Opening
0 44 feet (13.4 m) 34 feet (10.4 m)
1 34 feet (10.4 m) 26 feet (7.9 m)
2 26 feet (7.9 m) 20 feet (6.1 m)
3 20 feet (6.1 m) 14 feet (4.3 m)
Flexible Metal Duct
Number of
90º Elbows
Weather Hood
4-inch Opening
Weather Hood
2½-inch Opening
0 24 feet (7.3 m) 20 feet (6.1 m)
1 20 feet (6.1 m) 16 feet (4.9 m)
2 16 feet (4.9 m) 12 feet (3.7 m)
3 12 feet (3.7 m) 8 feet (2.4 m)
NOTE: Deduct 6 feet (1.8 m) for each additional elbow.
Level
Dryer
Base
Leveling
Leg
3
/
8
" NPT gas
connection
Black iron pipe
Shorter than 20' (6.1 m) - use
3
/
8
" pipe
Longer than 20' (6.1 m) - use
1
/
2
" pipe
Use new stainless steel flexible connector
only if allowed by local codes (Use Design A.G.A. certified connector)
1
/
8
" NPT pipe plug
(for checking inlet
gas pressure)
Install Equipment
shut-off valve
within 6' (1.8 m)
of dryer.
®
2000 Amana Appliances
Amana, Iowa 52204
Part No.40088806
Printed in U.S.A. 09/00
Question and Answer IconNeed help?

Do you have a question about the Speed Queen Gas Dryer and is the answer not in the manual?

Summary

Gas Dryer Installation Instructions

Keep Instructions for Future Reference

Keep these instructions for future reference. Consult the Owner's Manual for more details.

Questions About Installation

For any questions, refer to the Owner's Manual or contact support.

Optional Installation Kits

Various kits are available at the factory for installation needs.

Installation Preparation

Gather necessary items before starting installation, like ducting and tools.

Remove Parts and Clean Drum

Remove all parts from the dryer drum and clean it thoroughly.

Connect Dryer to Exhaust System

Connect the dryer to an external exhaust system for proper ventilation.

Connect Gas Supply

Connect the dryer to the gas supply, ensuring proper pressure and valve installation.

Connect Power Cord to Electricity

Connect the dryer's power cord to a suitable electrical outlet.

Important Safety Information

Ground Wire Safety

Proper grounding reduces electric shock risk by providing an escape wire.

Grounding Instructions

Ensure the dryer is properly grounded using a 3-prong plug and receptacle.

Electrical Shock Prevention

Disconnect power before servicing, ground properly, and check outlet.

Fire Prevention

Exhaust dryer outdoors only. Do not exhaust into enclosed spaces or vents.

Fire and Explosion Prevention

Follow manual instructions. Do not store flammable liquids near the appliance.

Gas Leak Safety

If you smell gas, do not light any appliance, do not use phones, call gas supplier.

Installation Requirements

Location Requirements

Place dryer on solid floor with adequate air supply. Consider closet door vents.

Electrical Requirements

Dryer needs 120V, 15A, 60Hz power and a 3-prong grounding plug.

Gas Supply Requirements

Ensure correct gas pressure and install shut-off valve. Convert for L.P. gas.

Exhaust System Requirements

Use rigid/semi-rigid metal duct. Exhaust dryer outdoors. Avoid plastic/foil ducting.

Installation Checks and Adjustments

Dryer Dimensions and Clearances

Review required space and clearances for proper dryer installation.

Checking and Adjusting Burner Flame

View burner flame through the front panel and adjust air shutter for optimal flame.

Summary

Gas Dryer Installation Instructions

Keep Instructions for Future Reference

Keep these instructions for future reference. Consult the Owner's Manual for more details.

Questions About Installation

For any questions, refer to the Owner's Manual or contact support.

Optional Installation Kits

Various kits are available at the factory for installation needs.

Installation Preparation

Gather necessary items before starting installation, like ducting and tools.

Remove Parts and Clean Drum

Remove all parts from the dryer drum and clean it thoroughly.

Connect Dryer to Exhaust System

Connect the dryer to an external exhaust system for proper ventilation.

Connect Gas Supply

Connect the dryer to the gas supply, ensuring proper pressure and valve installation.

Connect Power Cord to Electricity

Connect the dryer's power cord to a suitable electrical outlet.

Important Safety Information

Ground Wire Safety

Proper grounding reduces electric shock risk by providing an escape wire.

Grounding Instructions

Ensure the dryer is properly grounded using a 3-prong plug and receptacle.

Electrical Shock Prevention

Disconnect power before servicing, ground properly, and check outlet.

Fire Prevention

Exhaust dryer outdoors only. Do not exhaust into enclosed spaces or vents.

Fire and Explosion Prevention

Follow manual instructions. Do not store flammable liquids near the appliance.

Gas Leak Safety

If you smell gas, do not light any appliance, do not use phones, call gas supplier.

Installation Requirements

Location Requirements

Place dryer on solid floor with adequate air supply. Consider closet door vents.

Electrical Requirements

Dryer needs 120V, 15A, 60Hz power and a 3-prong grounding plug.

Gas Supply Requirements

Ensure correct gas pressure and install shut-off valve. Convert for L.P. gas.

Exhaust System Requirements

Use rigid/semi-rigid metal duct. Exhaust dryer outdoors. Avoid plastic/foil ducting.

Installation Checks and Adjustments

Dryer Dimensions and Clearances

Review required space and clearances for proper dryer installation.

Checking and Adjusting Burner Flame

View burner flame through the front panel and adjust air shutter for optimal flame.

Speed Queen Gas Dryer Specifications

General IconGeneral
BrandSpeed Queen
Capacity7.0 cu. ft.
Drum MaterialStainless Steel
Voltage120 V
Wrinkle Prevention OptionYes
CyclesMultiple
Energy SourceGas
Temperature SettingsMultiple
Warranty3-5 Year Limited Warranty (Varies by model)