4.3 Troubleshooting
Symptom
Check
No power
Ensure power is connected.
Check power supply meets requirements per
5.Specifications
Check the fuse inside the cigarette lighter plug. If
blown, a replacement fuse, PN: 100PLF100, can be
ordered. Please consult Spidertracks for approval of
alternative fuse options.
Power and green light
status but no flight
information on website
Ensure account registration and Spider activation steps
have been completed
Ensure Spider has been assigned to an aircraft.
Partial flight information
missing on website
Check the location of the Spider and follow guidance
per 2.2 Locate. The Spider must have a clear view of
the sky. Check there are no obstructions inside and
outside the aircraft (e.g. tall buildings).
Ensure there is nothing covering the Spider during
operation.
If the problem persists, contact
support@spidertracks.com and request further
analysis of the Spider performance.
3D flight replay issues
If mounting with fasteners, check supplied fasteners
are located in the correct mounting holes on the
bracket. Failure to do this can degrade performance.
Spider is signalling
updating software
The device automatically downloads new software
when in cell coverage to keep in sync with the features
of the system. It will update the software on the next
power cycle. It will not update when in flight. The
Spider is ready for use again when the status light has
returned to normal per 3.1 Operate.