EasyManua.ls Logo

Spirax Sarco UTM20 Series - Part Number Construction; Flow Meters for Pipes 2 and Smaller for Class I, Div 2 Hazardous Locations

Spirax Sarco UTM20 Series
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IM-P505-02-US Issue 1
92
UTM20 Series Ultrasonic Transit-time Flowmeters
14.2 UTM20 Flow Meters for Pipes 2" and Smaller for Class
I, Div 2 Hazardous Locations
Model UTM20 Ultrasonic Clamp-On Meter DQ
Certification Hazardous Location, Class I, Division 2 B
Transducer Type 1
½" ANSI Pipe CA
¾" ANSI Pipe CB
1" ANSI Pipe CC
1¼" ANSI Pipe CD
" ANSI Pipe CE
2" ANSI Pipe CF
½" Copper Tube CG
¾" Copper Tube CH
1" Copper Tube CT
1¼" Copper Tube CJ
" Copper Tube CK
2" Copper Tube CL
Transmitter Type
110/220V AC Remote Mounted R
24 VDC/AC Remote Mounted B
Display
Display and Keypad S
No Display/Keypad W
Remote Cable/Conduit
Length 2
15 feet (4.5 m) AC
30 feet (9 m) AF
50 feet (15 m) AK
75 feet (23 m) AR
100 feet (30 m) BW
Hardware
½" NPT Threads, Poly cable glands S
½" NPT Threads, Nickel Plated Brass cable glands T
½" NPT Threads, no cable glands N
M20 Threads, Poly cable glands C
M20 Threads, Nickel Plated Brass cable glands D
M20 Threads, no cable glands A
Endpoint Wiring Method None XX