Do you have a question about the Spirax Sarco ILVA20 and is the answer not in the manual?
Measuring Principle | Vortex Shedding |
---|---|
Material | Stainless steel |
Application | Liquid and gas flow measurement |
Sizes | DN15 to DN300 |
Output | 4-20 mA |
Process Connection | Flanged |
Protection Class | IP67 |
Pressure Rating | PN40 |
Temperature Limit | -40 to 250 °C (-40 to 482 °F) |
Measuring Range | Depends on medium and pipe size |
Process Temperature | -40 to 250 °C (-40 to 482 °F) |
Defines the product's intended application and compliance with directives.
Overview of the manual's scope and content for ILVA20 flowmeter.
Details the three main elements of the ILVA20 flowmetering system.
Specifies the available sizes and compatible flange types for the ILVA20.
Lists the materials used for various parts of the ILVA20 and MVT10.
Provides essential technical specifications like power supply, outputs, and communication ports.
Defines the operational pressure and temperature ranges for the ILVA20.
Presents dimensional and weight data for different ILVA20 sizes.
Provides dimensional and weight data for the MVT10 transmitter.
Guidelines for installing the product in suitable environmental conditions.
Specifies the correct orientation for installing the ILVA20 for accurate measurement.
Details requirements for pipework connected upstream and downstream of the ILVA20.
Discusses the importance of central location and gasket selection for accurate readings.
Explains the connection of impulse lines to the pressure tappings on the ILVA20.
Describes the general arrangement for using hard piping for impulse lines.
Instructions on how to mount the MVT10 transmitter bracket.
Provides warnings and general procedures for safe electrical wiring.
Details how to connect the 4-20 mA loop power to the MVT10.
Explains DC power and signal wiring for EIA/TIA-485 communication.
Guides on wiring the external temperature sensor to the MVT10.
Details the wiring connections for replacing the pressure sensor cable.
Describes how the MVT10 operates in run mode and displays data.
Explains how to enter and navigate the MVT10 commissioning mode.
Details the configuration options within the BASIC DATA sub-menu.
Covers the input settings, including zeroing sensors and configuring temperature inputs.
Details the configuration of 4-20mA, Modbus, and pulsed outputs.
Explains how to set up and configure various alarm functions.
Accesses diagnostic tools for testing display, outputs, and cancelling tests.
Provides information about the flowmeter and functions to clear totals or change pass codes.
Recommends periodic cleaning of impulse lines and provides cleaning instructions.
Guides on replacing spare parts like manifold seals and impulse hoses.
Lists the supported read holding registers for the MVT10.