Do you have a question about the Spirax Sarco UTM20 Series and is the answer not in the manual?
| Brand | Spirax Sarco |
|---|---|
| Model | UTM20 Series |
| Category | Measuring Instruments |
| Language | English |
Provides guidance for installing and maintaining the UTM20 series flowmeters.
Explains formatting conventions used in the manual for clarity.
Defines safety-related terms and hazard symbols used in the manual.
Outlines important safety considerations for installation and operation.
Presents dimensional drawings and specifications for the remote enclosure.
Provides dimensional information for the wall mount bracket accessory.
Details the dimensions for the panel mount enclosure option.
Explains how to use the keypad from the main display screen.
Describes keypad navigation and control within the meter's menu system.
Details how to select options from parameter lists on the display.
Explains the procedure for inputting numerical values using the keypad.
Provides a general overview of the installation steps for different transducer types.
Lists important factors and environmental requirements for transmitter mounting.
Specifies the tools and materials needed for installation.
Refers to the transducer user manual for specific transducer installation.
Step-by-step guide for installing the meter with fixed transducers.
Detailed steps for installing the meter with adjustable transducers.
Instructions for installing the meter into a customer-supplied panel.
Specifies the correct torque values for terminal screw connections.
Illustrates and defines common electrical symbols used in wiring diagrams.
Provides data on conductor cross-sections and AWG for connections.
Lists rated conditions for mains AC, DC power, transducer, and I/O terminals.
Guides on connecting the transducer cables to the transmitter terminals.
Details the wiring procedure for 9 to 28V DC power supply.
Explains how to connect a 20 to 26V AC power source to the transmitter.
Provides wiring instructions for mains AC power connection.
Details the wiring for the 4-20 mA analog output signal.
Illustrates wiring for digital outputs, including control outputs 1, 2, and 3.
Explains the RS485 serial communication output and its capabilities.
Shows wiring for digital inputs, specifically for resetting the totalizer.
Wiring diagram for connecting to AquaCUE/BEACON endpoints.
Wiring instructions for RTD temperature sensors in energy models.
Wiring details for the auxiliary output card.
Step-by-step guide for installing or removing the microSD card.
Procedure for connecting the meter to a computer via USB for programming.
Guides on setting up the meter using the keypad or software.
Access to configuration and setting menus for the meter.
Options for configuring the meter's display parameters.
Provides system information like model, serial number, and firmware version.
Tools for system status, history, and troubleshooting.
Functions for resetting flow totals or unlatching alarms.
Describes the hierarchical structure of the transmitter's firmware menus.
Defines measurement units and decimal settings for readings and totalizers.
Selection of the appropriate transducer type for the meter.
Options for mounting the transducers, refer to user manual.
Selection of the pipe material for accurate measurements.
Defines pipe type and size based on ASME/ANSI, ASTM, or material selection.
Lists available fluid types for measurement.
Sets the required spacing between transducers based on pipe parameters.
Sets flow direction, low flow cutoff, and signal strength settings.
Selects filtering method and sets damping, sensitivity, hysteresis, and BDR.
Selects calibration mode and defines zeroing methods (No Flow, Steady Flow).
Allows manual entry of zero values, sensor factors, and scale factors.
Assigns reading to output, sets range, min/max values, and failure mode.
Overrides output for testing and trims 4mA/20mA values.
Sets frequency output mode, source, value at 0 Hz, max value, and test frequency.
Sets pulse output mode, source, scaling factor, pulse width, and state.
Sets flow direction output mode, source, and direction settings.
Sets alarm mode, high/low thresholds, latching, and anti-chatter.
Configures internal or external pull-up resistors for outputs.
Configures mode, source, and direction/alarm settings for auxiliary outputs.
Selects action and state for digital input.
Configures RTD sensor type, range, delta temp, and trimming.
Configures EIA-485 type, Modbus RTU address, baud rate, access, parity, stop bits, resistor, word order, timeout.
Configures BACnet MS/TP MAC address, ID, baud rate, access, parity, stop bits, resistor.
Configures endpoint settings and BACnet/IP parameters like IP address, subnet mask, gateway, DNS.
Configures Modbus TCP/IP parameters including IP address, subnet mask, gateway, DNS.
Configures Ethernet/IP parameters including IP address, subnet mask, gateway, DNS.
Configures log mode, time interval, and parameters to log.
Configures the communication card type or disables card functionality.
Enables security features, sets access levels, and configures logout timeout.
Accesses recovery screen, enters temporary passcode, generates recovery code.
Selects display language, decimal format, and tag ID.
Adjusts display brightness, contrast, dimmer, and timeout.
Sets the current time and date on the meter.
Displays vendor, model, part number, serial number, firmware version, dates, and tag ID.
Shows signal strength, history, flow rate, temperatures, and overflow counts.
Displays status of outputs, inputs, and hardware options like MAC address.
Configures time, date, simulation mode, passcode level, clears history, resets, and reboots.
Step-by-step guide to reset the accumulated flow totalizer.
Unlatches outputs if alarm condition occurred and cleared.
Describes out-of-specification, error, and check function messages.
How to view buffered alarm or warning messages.
Lists warning and alarm codes with descriptions and corrections.
Lists check function codes and their corrections.
Lists out-of-specification codes and their corresponding corrections.
Lists out-of-specification codes and their corresponding corrections.
Lists out-of-specification codes and their corresponding corrections.
Troubleshooting steps for when the transmitter does not power up.
Guides to diagnose and correct incorrect flow readings.
Troubleshooting steps for unstable flow readings.
Diagnosing and correcting reversed flow direction readings.
Troubleshooting output mismatches with readings.
Step-by-step instructions for replacing the AC module.
Procedure for replacing the communication or dry contact board.
Instructions for replacing the main circuit board.
Guidance on updating the meter's firmware.
General system specs including liquid types and flow accuracy.
Details safety and hazardous location certifications.
Specs for power options, display, flow rate/total, enclosure, and construction.
Specs for environmental ratings and configuration methods.
Selectable units for velocity, volumetric total, flow rate, energy, and temperature.
Specs for inputs, outputs, USB, EIA-485, Ethernet, and AquaCUE/BEACON ports.
Specs for data logging, alarms, languages, and security features.
Details transducer models, construction, cable length, pipe sizes, and flow rate.
Details part numbers, descriptions, installation, type, construction, and temperature range for RTD kits.
Description and compatibility of the SoloCUE software.
Explains part number construction for flow meters up to 2 inches.
Part number construction for hazardous location flow meters.
Part number construction for flow meters 2.5 inches and larger.
Part number construction for hazardous location flow meters (2.5"+).
Part number construction for ATEX/EICEx hazardous location meters.
Part number construction for energy meters (pipes 2" and smaller).
Part number construction for energy meters (pipes 2.5"+).
Standard classes and dimensions for cast iron pipes (3-10 inch).
Standard classes and dimensions for steel, stainless steel, PVC pipes.
Dimensions for copper tubing, brass pipe, and aluminum pipe.