UTM20 Series Ultrasonic Transit-time Flowmeters
10.20 Display Menu
Requires operator level passcode or higher if security is enabled An asterisk (*) indicates the
parameter default
Display Submenus Options/Descriptions
LANGUAGE
*ENGLISH English
DEUTSCHE German
ESPAÑOL Spanish
FRANÇAIS French
ITALIANO Italian
DECIMAL
#.#
#,#
Select whether the decimal indicator is a period or a
comma
DISPLAY TAG ID
*DISABLED
ENABLED
Displays the TAG ID on the Home Screen Default is UTM20
Use SoloCUE to change the TAG ID
BRIGHTNESS Select the display brightness 10 to 100% in increments of 10 Default is 70%
CONTRAST Adjust the screen contrast 12 to 37 Default is 24
DIMMER
*ENABLED
DISABLED
Enable the DIMMER to reduce the display BRIGHTNESS
after the buttons are not pressed for the TIMEOUT period
Select the BRIGHTNESS level Default is 10%
DIMMER LEVEL
OFF
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Press any button to awaken the transmitter and return to
normal BRIGHTNESS The buttons pressed will not be
active for one second after the transmitter is awakened
TIMEOUT
5 MINUTES
*10 MINUTES
20 MINUTES
30 MINUTES
60 MINUTES
SET TIME Numeric entry for 24 hour clock HH:MM
SET DATE Numeric entry for date YYYY-MM-DD
DISPLAY TIME 24 HOUR AM / PM
Select format of the time to display on the Home Screen
and on the SoloCUE dashboard
DISPL AY DATE
YYYY-MM-DD
MM-DD-YYYY
DD-MM-YYYY
Select format of the date to display on the Home Screen
and on the SoloCUE dashboard