UTM20 Series Ultrasonic Transit-time Flowmeters
10.16 Setup > Data Logging (Service Level Access)
Requires service level passcode or higher if security is enabled
Due to FAT32 limitation on the microSD card, if the file size exceeds 4 GB, the log file will be closed
and a new file started Both files will be accessible The name of the files are FILE0001 txt, FILE0002
txt, and so on Log files are automatically saved as txt files to the microSD card Before removing the
microSD card, change the LOG MODE to DISABLED With an 8 GB microSD card installed, the card will
have enough memory to last about 1-1/2 years when logging 8 parameters at a 1 second time interval
Data Logging Submenus Options/Descriptions
LOG MODE
Log files can be transferred to a computer by using SoloCUE Data logging will
pause during the file transfer
New log file created when parameters are added or removed from data log
*DISABLED
CONTINUOUS Logs when transmitter is on and operating
THRESHOLD
Logs when the threshold value is between the minimum
and maximum values
For example, only log when process equipment is
operational and flow is above cutoff
TIME INTERVAL
1 SECOND 1 MINUTE 1 HOUR
2 SECONDS 2 MINUTES 2 HOURS
5 SECONDS 5 MINUTES 4 HOURS
10 SECONDS 10 MINUTES 6 HOURS
20 SECONDS 30 MINUTES 12 HOURS
30 SECONDS 24 HOURS
PARAMETER #1
to .
PARAMETER #8
Note: For error/alarm codes, the last 10 codes in the history are logged with
commas separating the values
FLOW RATE DELTA TRANSIT TIME
ENERGY TOTAL
FORWARD
FLOW TOTAL GROSS TEMPERATURE #1
ENERGY TOTAL
REVERSE
FLOW TOTAL FORWARD TEMPERATURE #2 ENERGY TOTAL NET
FLOW TOTAL REVERSE TEMP#1 - TEMP#2 SIGNAL STRENGTH
FLOW TOTAL NET TEMP#2 - TEMP#1 SOUND SPEED
VELOCITY ENERGY RATE ERROR/ALARM CODE
REYNOLDS ENERGY TOTAL GROSS NONE
THRESHOLD
If THRESHOLD control is selected, this setting will be active
FLOW RATE
FLOW TOTAL
TEMPERATURE #1
TEMPERATURE #2
DELTA TEMPERATURE
ENERGY RATE
ENERGY TOTAL
VELOCITY
MIN THRESHOLD Numeric entry (plus or minus)
If THRESHOLD log model is selected,
this setting will be active
MAX THRESHOLD Numeric entry (plus or minus)
If THRESHOLD log model is selected,
this setting will be active
DELETE LOG Will stop recording and delete all records Prompt with a confirmation screen