EasyManua.ls Logo

Spirax Sarco UTM20 Series - Setup > Meter Configuration; Transducer Type Selection; Mounting Options for Transducers

Spirax Sarco UTM20 Series
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IM-P505-02-US Issue 1
48
UTM20 Series Ultrasonic Transit-time Flowmeters
10.3 Setup > Meter
Contains all of the configuration parameters for setting the meter Requires service level passcode or
higher if security is enabled An asterisk (*) indicates the parameter default
Meter Submenus Options/Descriptions
TRANSDUCER
Select the transducer type:
UZ 2 MHZ Option UZ when ordered with the UTM20 meter
CX 2 MHZ
Options CA to CS and CZ when ordered with the
UTM20 meter
JZ / KZ EASYRAIL 1 MHZ
Options JZ and KZ when ordered with the UTM20
meter
NZ / RZ / WZ 1 MHZ
Options NZ, WZ and RZ when ordered with the UTM20
meter
HZ 1 MHZ Option HZ when ordered with the UTM20 meter
LZ / YZ 0 5 MHZ Option LZ when ordered with the UTM20 meter
MOUNTING
For mounting options, see the transducer user manual
Z PATH
*V PATH
W PATH
Cx TYPE
DTTC TYPE is substituted for MOUNTING when TRANSDUCER DTTC is selected as the
transducer type
CA: ½" ANSI
CB: ¾" ANSI
CC: 1" ANSI
CD: 1¼" ANSI
CE: 1½" ANSI
CF: 2" ANSI
CG: ½" COPPER
CH: ¾" COPPER
CJ: 1¼" COPPER
CK: 1½" COPPER
CL: 2" COPPER
CM: ½" SS TUBE
CN: ¾" SS TUBE
CP: 1" SS TUBE
CQ: 1¼" SS TUBE
CR: 1½" SS TUBE
CS: 2 SS IN TUBE
CT: 1" COPPER