Date d'émission : Janvier, 2019 Révision: 2 Page : 38/60
Problem Possible cause Solution
The auger is creating
noise as it rotates
The bell shaped shaft seal has been
replaced without lubrication or is
damaged
The auger has been incompletely or
incorrectly reassembled
Replace or clean and lubricate with the
lubricant provided with the machine
Check and correct
The CUT OUT light on
the right side panel is on
The filter is dirty and needs to be
cleaned
The unit is positioned too close to a
wall or other object restricting air
flow and causing the machine to
run at a higher temperature
The filter is not properly installed
The unit has been installed near a
heat source, such as a coffee
machine, ice maker or cold
beverage machine which expels hot
air from its vents, causing the
machine to run at a high
temperature.
Clean and replace filter following
instructions
Reposition unit to maximize ventilation
space (see installation figures)
Properly install filter see
Reposition unit to maximize ventilation
space (see installation figures)