EasyManuals Logo

SPX FLOW APV DELTA SW4 User Manual

SPX FLOW APV DELTA SW4
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
11
APV_SW4_UK-4_082017.indd
UK
Single seat and change-over valve
DELTA SW4
Instruction manual: UK - rev.4
APV
9. Technical Data
9.1. General data
- Product-wetted parts: 316 L, 1.4404 (DIN EN
10088)
- Other parts: 1.4301 (DIN EN 10088)
- Seals: standard design: EPDM
- Option: HNBR, VMQ, HNBR
- Max. line pressure: 10 bar
- Operating pressure: depending on actuator
- see 9.6
- Max. operating temperature: 135°C EPDM, HNBR
*FPM, *VMQ
- Short-term load: 140°C EPDM, HNBR
*FPM, *VMQ
*(no steam)
- Air connection (for hose): 6 x 1mm
- Max. pneumatic air pressure: 8 bar
- Min. pneumatic air pressure: 6 bar
Use dry and clean air, only.
9.2. Compressed air quality
- Compressed air quality: quality class according to ISO 8573-1
- Content of solid particles: quality class 3,
max. number of particles per m³
10000 of 0,5 μm < d ≤ 1,0 μm
500 of 1,0 μm < d ≤ 5,0 μm
- Content of water: quality class 3,
max. dew point temperature - 20 °C
For installations at lower temperatures
or at higher altitudes, additional
measures must be considered to reduce
the pressure dew point accordingly.
- Content of oil: quality class 1,
max. 0,01 mg/m³
The oil applied must be compatible with Polyurethane elastomer
materials.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SPX FLOW APV DELTA SW4 and is the answer not in the manual?

SPX FLOW APV DELTA SW4 Specifications

General IconGeneral
BrandSPX FLOW
ModelAPV DELTA SW4
CategoryMeasuring Instruments
LanguageEnglish