GENERAL SAFETY INFORMATION
1. Pressurized devices
This equipment is a pressure containing device.
• Donotexceedmaximumoperatingpressureas
shown on equipment serial number tag.
• Makecertainequipmentisdepressurizedbefore
servicing.
2. Electrical
This equipment requires electricity to operate.
• Installequipmentincompliancewithnationaland
local electrical codes.
• StandardequipmentissuppliedwithNEMA1elec-
tricalenclosuresandisnotintendedforinstallation
inhazardousenvironments.
• Disconnectpowersupplytoequipmentwhenper-
forminganyelectricalservicework.
3. Breathing air
• Airtreatedbythisequipmentmaynotbesuitable
forbreathingwithoutfurtherpurication.Referto
OSHAstandard1910.134fortherequirementsfor
breathing quality air.
Contents
GENERALSAFETYINFORMATION ...................................1
1.0 INSTALLATION ..........................................................2
2.0 OPERATION ..............................................................3
3.0 MAINTENANCE ........................................................4
TROUBLESHOOTINGGUIDE .............................................6
SPECIFICATIONS ......................................................... 7-8
ELECTRICALSCHEMATICS ...............................................9
DIMENSIONSANDWEIGHTS ................................... 10-12
PARTSLIST .............................................................. 13-14
WARRANTY ..................................................................16
7610.724.27 Rev. D 9/09
Catalog No.: 3227482

Questions and Answers:

SPX HANKISON HIT Series Specifications

General IconGeneral
ApplicationIndustrial
ModelHIT Series
TypeDesiccant Dehumidifier
Dew Point-40°F (-40°C)
DimensionsVaries by model
WeightVaries by model

Summary

General Safety Information

1.0 Installation

1.1 Location

Placement of the dryer relative to air intake and required clearance.

1.2 Mounting

Covers floor or shelf mounting options for the dryer unit.

1.3 Piping Connections

Details connecting air inlet, outlet, and bypass piping with strainers.

1.4 Electrical Connections

Explains connecting the dryer to a power supply and adhering to electrical codes.

2.0 Operation

2.1 Start-up

Describes the initial start-up procedure for the refrigeration system.

2.2 Operating Check Points

Lists routine checks for proper dryer operation, including switch and fault light.

2.3 Minimum/Maximum Operating Conditions

Specifies required air pressure, temperature, and ambient conditions for operation.

3.0 Maintenance

3.1 Ambient Air Filter

Instructions for cleaning the ambient air filter, including removal and washing.

3.2 Inlet Strainer

Steps for cleaning or replacing the inlet strainer monthly or as needed.

3.3 Replace Separator/Filter Element

Guide on yearly replacement of the separator/filter element for optimal performance.

3.4 Automatic Condensate Drain

Troubleshooting Guide

A) Water Downstream of Dryer

Lists causes and corrective actions for water appearing downstream of the dryer.

B) High Pressure Drop Across Dryer

Explains potential causes for high pressure drop and their solutions.

C) Fault Alarm

Addresses issues related to fault alarms and their troubleshooting.

D) Refrigeration System Not Functioning Properly

Covers troubleshooting for the refrigeration system, including compressor cycling.

Specifications - Models 20 thru 75

Specifications - Models 100 and 125

Electrical Schematics

Dimensions and Weights

Dimensions and Weights

Dimensions and Weights

Parts List

Parts List

Notes

Warranty