INSTRUCTION MANUAL
SERVICE DEPARTMENT: (724) 746-1100
HIT SERIES
HIGH INLET
TEMPERATURE
REFRIGERATED
COMPRESSED
AIR DRYERS
GENERAL SAFETY INFORMATION
1. Pressurized devices
This equipment is a pressure containing device.
• Donotexceedmaximumoperatingpressureas
shown on equipment serial number tag.
• Makecertainequipmentisdepressurizedbefore
servicing.
2. Electrical
This equipment requires electricity to operate.
• Installequipmentincompliancewithnationaland
local electrical codes.
• StandardequipmentissuppliedwithNEMA1elec-
tricalenclosuresandisnotintendedforinstallation
inhazardousenvironments.
• Disconnectpowersupplytoequipmentwhenper-
forminganyelectricalservicework.
3. Breathing air
• Airtreatedbythisequipmentmaynotbesuitable
forbreathingwithoutfurtherpurication.Referto
OSHAstandard1910.134fortherequirementsfor
breathing quality air.
Contents
GENERALSAFETYINFORMATION ...................................1
1.0 INSTALLATION ..........................................................2
2.0 OPERATION ..............................................................3
3.0 MAINTENANCE ........................................................4
TROUBLESHOOTINGGUIDE .............................................6
SPECIFICATIONS ......................................................... 7-8
ELECTRICALSCHEMATICS ...............................................9
DIMENSIONSANDWEIGHTS ................................... 10-12
PARTSLIST .............................................................. 13-14
WARRANTY ..................................................................16
7610.724.27 Rev. D 9/09
Catalog No.: 3227482

Questions and Answers

  • R
    Rachel HowardAug 19, 2025
    Why is there a high pressure drop across my SPX HANKISON HIT 50?
    • C
      Catherine MooreAug 19, 2025
      A high pressure drop across your SPX Dehumidifier can be caused by: * A clogged inlet air strainer: Clean the inlet air strainer. * Excessive air flow: Check the flow rate. * A clogged separator filter: Replace the filter sleeve.
  • T
    Taylor HayesAug 29, 2025
    What to do if the refrigeration system is not functioning properly on my SPX HANKISON HIT 50?
    • D
      Danielle HernandezAug 29, 2025
      If the refrigeration system of your SPX Dehumidifier isn't functioning properly, it could be due to: * Power failure: Check the power to the unit. * Open line disconnect switch: Close the disconnect switch. * Blown fuses or open breaker: Check for continuity. * Faulty wiring or loose terminals: Have an electrician check the electrical connections. * High or low ambient conditions: Check the minimum/maximum temperature ranges. * Clogged ambient air filter: Clean the ambient air filter. * Clogged condenser fins: Clean the condenser. * Fan motor or fan control switch malfunction: Replace the fan motor or fan control switch. * Low voltage: Check the wiring.
  • F
    Franklin WernerNov 8, 2025
    What to do if there is water downstream of my SPX HANKISON HIT 50 Dehumidifier?
    • P
      patricia59Nov 8, 2025
      If there's water downstream of your SPX Dehumidifier, it could be due to several reasons: * Residual moisture in downstream pipelines: Blow out the system with dry air. * Open air bypass system: Check the valve positions. * Reversed inlet and outlet connections: Ensure correct connections. * Low temperatures around downstream air lines: Insulate or heat trace air lines exposed to low ambients, or use dry air to lower the dew point. * Excessive moisture at the dryer inlet: Install a separator ahead of the dryer. * Condensate not draining automatically: Replace the drain mechanism if it's not working. * Restricted or frozen drain line: Open the drain line. * Dryer overload: Check the inlet air temperature, pressure, flow rate (compressor capacity), and ambient air temperatur...

Summary

General Safety Information

Pressurized Devices Safety

Safety precautions for equipment operating under pressure.

Electrical Safety Guidelines

Instructions for safe electrical installation and operation.

Installation Procedures

Location Selection

Guidance on choosing an appropriate installation site.

Operation Guide

Start-up Sequence

Detailed steps for initiating the dryer's operation.

Maintenance Procedures

Troubleshooting Guide

Water Downstream Issues

Causes and solutions for moisture in output air.

High Pressure Drop Diagnosis

Identifying and resolving increased pressure loss.

Fault Alarm Resolution

Interpreting and rectifying alarm indicators.

Refrigeration System Malfunctions

Troubleshooting compressor cycling and system failures.

Electrical Schematics and Components

Parts List and Maintenance Kits

Warranty Information

Warranty Period and Terms

Details on coverage duration and warranty conditions.

SPX HANKISON HIT 50 Specifications

General IconGeneral
BrandSPX
ModelHANKISON HIT 50
CategoryDehumidifier
LanguageEnglish

Related product manuals