15
© SPX
Form No. 1000572
Rev. 0 February 8, 2012
Performance Specications
The information in the following charts can be used as a basis to determine if the system is performing
as expected during operation.
Pump RPM
Amp Draw at
690 bar (10,000
psi) (115V)
Amp Draw at
690 bar (10,000
psi) (230V)
dB A at Idle
and 690 bar
(10,000 psi)
Air Supply
Req'd bar (psi)
PE18 12,000 10.2 N/A 85/90 N/A
Pump
Max. Pressure
Output bar (psi)
Fluid Delivery* (cu. in./min. @)
0 bar (0 psi) 7 bar
(100 psi)
50 bar
(700 psi)
70 bar
(1,000 psi)
345 bar
(5,000 psi)
690 bar
(10,000 psi)
PE18 690 bar
(10,000 psi)
230 190 - - 25 18
* Typical delivery. Actual ow varies with eld conditions.
Table 3. Drive Unit Requirements
Table 4. Fluid Pressure Chart