9Power Meter Reboot
Power Meter Reboot
A power meter reboot drains voltage stored in the electronics, and resets the power meter operation.
Use your fingers to rotate the battery compartment lid
counter-clockwise and remove the lid. Remove the battery and
set it aside.
NOTICE
Do not use any tools to remove the battery lid. Tools can permanently
damage the power meter making it inoperable.
WARNING
Consult the battery manufacturer for safe handling instructions. Keep
the battery out of reach of children. Do not put the battery in your
mouth. If ingested, seek medical attention immediately. Do not use
sharp objects to remove batteries.
Use pliers to make contact on the battery compartment screw and the
threads on the battery compartment at the same time. Hold the pliers
in place 3-5 seconds, then remove.
Alternative method: Install two coins into the battery compartment.
Install the battery compartment lid. Wait 3-5 seconds, then remove the
battery compartment lid and coins.
NOTICE
The height of the coins must equal the height of the CR2032 battery.
The reboot will not be successful if the coins used are not the same
height as the battery.
1
2
Needle-nose pliers