12Battery Compartment Removal (Legacy Power Meters Only)
Battery Compartment Removal (Legacy Power Meters Only)
NOTICE
The following section, Spider Inspection, should only be performed on
a Legacy power meter. Do NOT perform the spider inspection service
on a DZero™ platform power meter. DZero platform power meters
include, but are not limited to DZero, DFour™, and XX1™ Eagle® power
meters.
If you remove the battery compartment on a DZero platform power
meter, you will damage the unit and void the warranty.
Use your fingers to rotate the battery lid counter-clockwise and remove
the lid. Remove the battery and set aside.
WARNING
Consult the battery manufacturer for safe handling instructions. Keep
the battery out of reach of children. Do not put the battery in your
mouth. If ingested, seek medical attention immediately. Do not use
sharp objects to remove batteries.
NOTICE
Do not use any tool to remove the battery lid. Tools can permanently
damage the power meter making it inoperable. The lid should be
loosened by hand.
Remove the battery compartment screw. Remove the battery
compartment screw assembly and battery compartment, and set them
aside.
NOTICE
Do NOT remove the battery compartment on a DZero platform power
meter, you will damage the unit and void the warranty. The DZero
platform power meter has a green LED blink on when awake. Do not
proceed if a green LED blinks on.
A Legacy power meter has a red LED blink on when the power meter
is awake.
Red LED Legacy Power Meter
1
2
T10