Coast Station data communication protocol
Page 20
This command will clear (erase) all logged data. This is irreversible. Data logging should be stopped using the
stop command documented above prior to clearing the log. Once the log has been cleared logging may be
restarted either by power cycling the Coast Station, or using the start logging command provided below. The
acknowledgement response is of the format:
\s:COAST STATION 1,c:1409653081,t:LIVE*6C\$PSMT,CST,CLEARLOGS,ACK*75
6.3.7 Start data logging process
$PSMT,CST,STARTLOGGING*5D
This command re-starts the internal data logging process. Note that data logging will be automatically restarted
if power to the Coast Station is cycled. The acknowledgement response is of the format:
\s:COAST STATION 1,c:1409649461,t:LIVE*6D\$PSMT,CST,STARTLOGGING,ACK*38