EasyManua.ls Logo

Stabila 196 electronic IP65 User Manual

Stabila 196 electronic IP65
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operating Instructions196 electronic IP65
196 M electronic IP65
EN
Question and Answer IconNeed help?

Do you have a question about the Stabila 196 electronic IP65 and is the answer not in the manual?

Stabila 196 electronic IP65 Specifications

General IconGeneral
IP RatingIP65
Laser Class2
Measuring accuracy with electronic inclination measurement± 0.1°
Laser Wavelength635 nm
TypeElectronic
Measuring accuracy in normal position±0.2 mm/m
Measuring accuracy in reverse position±0.2 mm/m

Summary

Battery Management

Display and Guidance Features

Angle Alignment Guides

Visual and acoustic cues guide the user to precise horizontal or vertical positions.

Measurement Unit Settings

Selecting Measurement Units

How to change display units (degrees, percent, mm/m, in/ft) using the MODE button.

Reference Angle Functionality

Setting a Reference Angle

Use the REF button to designate any angle as the new zero reference point.

Measurement Memory

Saving Current Measurement

Store the current measurement value using the HOLD button.

Power Management Features

Tilt Functionality

Tilt Prevention Mechanism

Prevents erroneous readings if the spirit level is tilted beyond acceptable limits.

Accuracy Verification

Performing Accuracy Check

Steps to verify and ensure the precise accuracy of the electronic spirit level.

Calibration Procedures

Single-Point Calibration

Align unit to a wall and press CAL to calibrate for basic accuracy.

Multi-Position Calibration

When Multi-Position Calibration is Needed

Triggers for recalibration: deviation, reference change, temperature change.

Calibration Step 1 (Horizontal)

Align unit horizontally and confirm with CAL button.

Related product manuals