EN
- 36 -
5. Table of errors
Error code Error description
EP 1
lling time exceeded, but a second attempt was undertaken
EP 2
double lling time exceeded, attempts terminated
E1 LO
temperature of probe T1 is too low (below 0ºC) (or an open circuit in the probe)
E1 HI
temperature of probe T1 is too high (above 110ºC) (or a short circuit in the probe)
E2 LO
temperature of probe T2 is too low (below 0ºC) (or an open circuit in the probe)
E2 HI
temperature of probe T2 is too high (above 110ºC) (or a short circuit in the probe)
E3 LO
temperature of probe T3 is too low (below 0ºC) (or an open circuit in the probe)
E3 HI
temperature of probe T3 is too high (above 110ºC) (or a short circuit in the probe)
E4
power outage during the operation of the dishwasher
Et
boiler overheating
E1
temperature dierence between probe T1 and T2 is too high (>30ºC)
E2
safety temperature exceeded – error displayed after the completion of emergency rinsing
6. Start-up of the device
Turn on the switch located on the wall, open the dishwasher door, place the overow plug in the appropria-
te place (g. 8) and close the door of the device. Press the
switch button . After the tank and the
boiler are lled with water, the boiler heating element will start operation. After the heating of water in
the boiler is completed, the dishwasher chamber water heating cycle will begin. Insert the basket into the
device chamber and wait until the water in the chamber reaches the set temperature. Before starting the
wash cycle, it is necessary to select the program. The wash cycle is activated automatically by opening and
closing the dishwasher door. If the door is opened during the wash cycle, the program stops automatically.
After the door is closed, the program continues the wash cycle. The completion of the wash cycle program is
indicated by a sound signal from the control board. Remove the basket from the device chamber.
Water for washing
60-65ºC (140-149°F)
Water for rinsing/sanitizing
82-90ºC (181-194°F)
7. Emptying of the tank in models equipped with a drain pump
Turn the device o by pressing the
switch , then open the door of the device, remove the overow
plug and close the door. Turn the drain pump on using the
button. The draining process
proceeds automatically until the tank is completely emptied of water. In order to reactivate the device, put
the overow plug back in its place, close the door and press the On/O switch. However, if the device will
not be used any more, turn the main switch o.
8. Emptying of the tank in models not equipped with a drain pump
Turn the device o by pressing the
the switch , then open the door of the device, remove the overow
plug and wait until the water is drained o completely from the tank. Put the overow plug back in its place, close
the door of the device.
Do not turn the device o when the water is still in the tank. Before turning the device o, always empty the
tank of water. In the event the device will no longer be used, after the completion of the above and the possible
initiation of a regeneration cycle, it is necessary to turn the device o by pressing the switch. The main switch should
then be turned o and the water valve should be closed.