EasyManua.ls Logo

Stanley 76001 - Page 13

Stanley 76001
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
ENGLISH
FITTING THE PIN TAIL DEFLECTOR KIT
IMPORTANT - READ THE SAFETY WARNINGS LISTED IN THE PROSET XT1 AND PROSET XT2 INSTRUCTION
MANUAL CAREFULLY BEFORE PUTTING INTO SERVICE.
IMPORTANT - THE AIR SUPPLY MUST BE TURNED OFF OR DISCONNECTED BEFORE FITTING OR
REMOVING THE PIN TAIL DEFLECTOR KIT.
Refer to  g. 12 and the table 4 on page 9. Refer also to the ProSet XT1 and ProSet XT2 Service Manuals.
Item numbers in bold refer to  g. 12 and table 5, 6.
The air supply must be disconnected.
Install Ejector Assembly (TRM00494) and Return Spring (TP144-082).
Screw End Cap (TP153-112) together with O-Ring (TP154-110), Ejector Guide (TP144-063).
Fit Collector Adaptor (TP153-111) together with MCS Valve Pusher (TP144-142).
Place Collector Adaptor Cover (TRM00033) over Collector Adaptor (TP153-111) and then install De ector
Adaptor (TRM00492) until the end face of Collector Adapter Cover (TRM00033) is secure against the
mating face of Collector Adapter (TP153-111).
• Fit De ector (PRG510-56) to De ector Adaptor (TRM00492).
Table 5 - TRM00305 - DEFLECTOR KIT for XT1
Item Part Number Description Qty
1 TRM00033 Collector Adaptor Cover 1
2 TRM00492 De ector Adaptor Assembly 1
3 PRG510-56 De ector 1
4 TRM00493 Ejector Assembly 1
Table 6 - TRM00306 - DEFLECTOR KIT for XT2
Item Part Number Description Qty
1 TRM00033 Collector Adaptor Cover 1
2 TRM00492 De ector Adaptor Assembly 1
3 PRG510-56 De ector 1
4 TRM00494 Ejector Assembly 1