10
G
B
the safety valve or remove its seal. Actuate the safety
valve from time to time to ensure that it works when
required. Pull the ring with sufficient force until you can
hear the compressed air being released. Then release
the ring again.
6.4 Storage
Warning!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Warning!
Store the compressor only in a dry location which
is not accessible to unauthorized persons.
Always store upright, never tilted!
7. DISPOSAL AND RECYCLING
The unit and its accessories are made of various types
of material, such as metal and plastic.
Defective components must be disposed of as special
waste. Ask your dealer or your local council.
8. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT CAUSE REMEDY
Leakage of air from the valve
of the pressure switch with the
compressor off.
Check valve that, due to wear or
dirt on the seal, does not perform
its function correctly.
Unscrew the hexagonal head of
the check valve, clean the valve
seat and the special rubber disk
(replace if worn). Reassemble and
tighten carefully.
Reduction of performance.
Frequent start-up. Low pressure
values.
Excessiveperformancerequest,
check for any leaks from the
couplingsand/orpipes.Intakelter
may be clogged.
Replacethesealsofthetting,
cleanorreplacethelter.
The compressor stops and restarts
automatically after a few minutes.
Tripping of the thermal cutout due
to overheating of the motor.
Clean the air ducts in the
conveyor. Ventilate the work area.
After a few attempts to restart, the
compressor stops.
Tripping of the thermal cutout
due to overheating of the motor
(removal of the plug with the
compressor running, low power
voltage).
Activate the on/off switch. Ventilate
the work area. Wait a few minutes.
The compressor will restart
independently.
The compressor does not stop and
the safety valve is tripped.
Irregular functioning of the
compressor or breakage of the
pressure switch.
Remove the plug and contact the
Service Center.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts.
Tampering with the machine may impair its safety and in any case make the warranty null and void.