9
G
B
servicing to qualified service personnel. Never remove
any part of the casing unless qualified to do so; this unit
contains dangerous voltages.
Warning!
For your protection if this product is to be used outdoors
it should not be exposed to rain or used in damp
locations. Do not place the product on damp surfaces,
use a workbench if available. For added protection use
a suitable residual current device (R.C.D.) at the socket
outlet.
Note: If the mains cable requires replacing it must be
replaced with an identical one and fitted by a
qualified person.
5.4 On/Offswitch(ref.8)
To switch on the equipment set the On/Off switch (ref.
8) to position I.
MovetheOn/Offswitch(ref.8)topositionO to switch
off the equipment.
5.5 Adjusting the pressure
● Youcanadjustthepressureonthepressuregauge
(ref. 6) using the pressure regulator (ref. 7).
● Thesetpressurecanbetakenfrom the quicklock
coupling (ref. 5).
5.6 Settingthepressureswitch
The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar
6. CLEANING AND MAINTENANCE
Warning!
Pull the power plug before doing any cleaning and
maintenance work on the appliance.
Warning!
Wait until the compressor has completely cooled
down. Risk of burns!
Warning!
Always depressurize the tank before carrying out
any cleaning and maintenance work.
6.1 Cleaning
● Keepthesafetydevicesfreeofdirtanddustasfar
as possible. Wipe the equipment with a clean cloth or
blow it with compressed air at low pressure.
● We recommend that you clean the appliance
immediately after you use it.
● Clean the appliance regularly with a damp cloth
and some soft soap. Do not use cleaning agents
or solvents; these may be aggressive to the plastic
partsintheappliance.Ensurethatnowatercanget
into the interior of the appliance.
● Youmustdisconnectthehoseandanysprayingtools
from the compressor before cleaning. Do not clean
the compressor with water, solvents or the like.
6.2 Condensationwater
The condensation water must be drained off each day
by opening the drain valve (ref. 11) (on the bottom of the
pressure vessel).
Warning!
The condensation water from the pressure vessel
will contain residual oil. Dispose of the condensation
water in an environmentally compatible manner at
the appropriate collection point.
6.3 Safetyvalve(ref.10)
The safety valve has been set for the highest permitted
pressure of the pressure vessel. It is prohibited to adjust
MAINTENANCE RESUMPTIVE TABLE
FUNCTION
AFTER THE FIRST
100 HOURS
EVERY 100 HOURS
Cleaning of intake filter and/or
substitution of filtering element
● ●
Draining tank condensate Periodically and at the end of work