RECOMMENDED FUELS
All fuels should be stored under cover and kept as dry as possible prior to use.
This appliance has been tested using seasoned wood logs and manufactured briquetted smokeless fuel (Ancit)
for closed appliances, sized between 20g and 140g. Other fuels are commercially avail-able and may give sim-
ilar results. Wood logs up to 300mm long are suitable. All fuels should be stored under cover and kept as dry
as possible prior to use.
Do not use fuels with a Petro-coke ingredient as this may cause the grate to overheat, causing damage.
Reduced outputs will result when fuels of lower calorific values are used. Never use gasoline or gasoline type
lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or freshen up a fire in this heater. Keep all
such liquid well away from the heater at all times. Operate the stove only with the fuelling door closed except
for re-fuelling.
This stove has obtained HETAS Ltd approval as an ‘intermittent’ operating appliance for burning Natural wood
logs and manufactured smokeless fuels as detailed in recommended fuels below. HETAS Approval does not
cover the use of other fuels either alone or mixed with the recommended fuels listed, nor does it cover instruc-
tions for the use of other fuels.
AOIFE - TECHNICAL DATA FUEL
Coal Wood
Parameter
Max Heat Output (kW) 7.3 6.6
Nominal Heat Output (kW) 7.3 6.6
Output to Room (kW) 7.3 6.6
Typical Refuel Interval To
Achieve Nominal Outputs (h)
1.00 .75
Mean Flue Gas Temp. (
o
C) 311 343
Gross Weight (kg) 105
Flue Outlet Diameter (mm) 125
Wood Log Size (mm) N/A 300
Model
Energy
Efficiency
Class
Heat Output
to Room
Heat Output
to Water
Energy
Efficiency
Index
Preferred
Fuel
Nominal
Heat
Output
Net Efficiency
Aoife A 6.6 N/A 94.1 Wood 6.6 71.1
LIGHTING
Before lighting the stove check with the installer that the installation work and commissioning checks described
previously have been carried out correctly and that the chimney has been swept clean, is sound and free from
any obstructions. As part of the stoves commissioning and handover the installer should demonstrate how to
operate the stove correctly.