6.3 Safety valve (ref. 10)
The safety valve has been set for the highest
permitted pressure of the pressure vessel. It is
prohibited to adjust the safety valve or remove its
seal.Actuatethesafetyvalvefromtimetotimeto
ensurethatitworkswhenrequired.Pulltheringwith
sufficient force until you can hear the compressed
airbeingreleased.Thenreleasetheringagain.
6.4 Storage
Warning!
Pull the mains plug out of the socket and
ventilate the appliance and all connected
pneumatic tools.
Switch off the compressor and make sure that it
is secured in such a way that it cannot be started
up again by any unauthorized person.
Warning!
Store the compressor only in a dry location which
is not accessible to unauthorized persons.
Always store upright, never tilted!
7. DISPOSAL AND RECYCLING
The unit and its accessories are made of various
typesofmaterial,suchasmetalandplastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local
council.
8. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT CAUSE REMEDY
Leakage of air from the valve
of the pressure switch with
thecompressoroff.
Check valve that, due to wear
or dirt on the seal, does not
performitsfunctioncorrectly.
Unscrew the hexagonal head
of the check valve, clean the
valve seat and the special
rubberdisk(replaceifworn).
Reassemble and tighten
carefully.
Reductionofperformance.
Frequentstart-up.Low
pressurevalues.
Excessive performance
request, check for any leaks
from the couplings and/or
pipes.Intakeltermaybe
clogged.
Replace the seals of the
tting,cleanorreplacethe
lter.
Thecompressorstopsand
restarts automatically after a
fewminutes.
Trippingofthethermalcutout
due to overheating of the
motor.
Clean the air ducts in the
conveyor.Ventilatethework
area.
After a few attempts to
restart,thecompressor.
Trippingofthethermalcutout
due to overheating of the
motor(removaloftheplug
with the compressor running,
lowpowervoltage).
Activatetheon/offswitch.
Ventilatetheworkarea.
Waitafewminutes.The
compressor will restart
independently.
Thecompressordoesnot
stop and the safety valve is
tripped.
Irregular functioning of the
compressor or breakage of
thepressureswitch.
Remove the plug and contact
theServiceCenter.
Any other type of operation must be carried out by authorized Service Centers, requesting
original parts. Tampering with the machine may impair its safety and in any case make the
warranty null and void.

Table of Contents

Other manuals for Stanley D 200/8/24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stanley D 200/8/24 and is the answer not in the manual?

Stanley D 200/8/24 Specifications

General IconGeneral
BrandStanley
ModelD 200/8/24
CategoryAir Compressor
LanguageEnglish

Related product manuals