EasyManua.ls Logo

Stanley D 240/10/24 - Disposal and Recycling

Stanley D 240/10/24
104 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
G
B
Warning!
Store the compressor only in a dry location
which is not accessible to unauthorized per-
sons. Always store upright, never tilted!
7. DISPOSAL AND RECYCLING
The unitand its accessories are madeof various
typesofmaterial,suchasmetalandplastic.Defec-
tive components must be disposed of as special
waste.Askyourdealeroryourlocalcouncil.
8. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT CAUSE REMEDY
Leakage of air from the valve
of the pressure switch with the
compressoroff.
Check valve that, due to wear
or dirt on the seal, does not
performitsfunctioncorrectly.
Unscrew the hexagonal head of
the check valve, clean the valve
seat and the special rubber disk
(replaceifworn).Reassemble
andtightencarefully(gures
14-15).
Reductionofperformance.
Frequentstart-up.Lowpressure
values.
Excessive performance request,
check for any leaks from the
couplingsand/orpipes.Intake
ltermaybeclogged.
Replacethesealsofthetting,
cleanorreplacethelter.
Thecompressorstopsand
restarts automatically after a few
minutes.
In the V, 3 HP versions, it is does
notstart.
Trippingofthethermalcutout
duetooverheatingofthemotor.
Clean the air ducts in the
conveyor.Ventilatethework
area.Resetthethermalcutout.
On lubricated and V type
models, check oil level and
quality.OnVmodels,havethe
voltagechecked.
After a few attempts to restart,
thecompressor.
Trippingofthethermalcutout
due to overheating of the motor
(removaloftheplugwiththe
compressor running, low power
voltage).
Activatetheon/offswitch.
Ventilatetheworkarea.Waita
fewminutes.Thecompressor
willrestartindependently.OnV,
3 HP models, reset the thermal
cutout.Removeanypowercable
extensions.
Thecompressordoesnotstop
andthesafetyvalveistripped.
Irregular functioning of the
compressor or breakage of the
pressureswitch.
Remove the plug and contact
theServiceCenter.
Any other type of operation must be carried out by authorized Service Centers, requesting original
parts. Tampering with the machine may impair its safety and in any case make the warranty null
and void.