iQ Control Box
01.25.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204144 REV B 13
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
Index Min
Value
Max
Value
Description Defaults
Single Dual
31 1 99* Close Learn
Speed
Close Learn Speed is the speed used on power up,
during FIS and aer an obstrucon. The controller
display may indicate either 07 or 09 as a door state
and sll use Close Learn Speed based on the
condions listed prior.
This speed is typically set higher than check speed,
to allow faster door moon when not in the check
zones, but sll slower door moon than normal
operaon.
This parameter sets the target speed seng. Other
parameters like close learn torque and close
acceleraon as well as door properes like fricon,
door length, and door weight aect door speed.
20 20
32 1 99 Close Learn
Torque
Close Learn Torque is the torque used on power up,
during FIS, aer an obstrucon.
This torque must be set to comply with ANSI/
BHMA door force requirements.
This parameter sets the maximum current available
to the motor which is directly proporonal to the
door force. This torque seng is used in
conjuncon with Close Learn Speed.
30 25
33 0 99 Close Startup
Length
Close Startup Length is the percent of door length
in which Close Startup Torque parameter is used.
These parameters are used to overcome fricon
encountered at the begining of close door moon.
This parameter should be set as low as possible to
ensure reliable operaon.
0 0
35 1 99 Close Startup
Torque
Close Startup Torque is the torque used when
entering the closing state (07). It is used for a
congurable door length (determined by the Close
Startup Length parameter). Aer this door length,
the torque seng will revert to the Close Torque.
This torque should be set greater than Close Torque
to ensure that the controller can start door moon,
overcome stac fricon, and avoid obstrucons.
This torque must be set to comply with ANSI/BHMA
door force requirements.
This parameter sets the maximum current available
to the motor which is directly proporonal to the
door force.
35 25