iQ Control Box
01.25.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204144 REV B 17
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
Status Code Description Remediation IF Necessary
00 Normal operaon—All OK
20 Breakout
33 System error See aachment 7
34 Internal communicaon error – Type 1 See aachment 7
35 Motor drive failure Replace controller
36 Internal communicaon error – Type 2 See aachment 7
0b Obstrucon
A0 First Installaon Sequence (FIS)
A1 Auto-conguraon sequence
A2 Auto-conguraon conrmaon sequence
b1 Encoder error > cable failure Verify magnet/encoder pair
b2 Encoder mismatch > wrong encoder/magnet Verify magnet/encoder pair
b3 Encoder fault > wrong encoder/magnet or
cable falure
Verify magnet/encoder pair
bE Blocked egress
c1 Posion learn error
Ld Lock down (shear lock energized)
db Output control See Aachment 6, Sheet 2 of 2
dc Display door cycle counter
dE Delayed egress
d0 Free egress
E2 Door held open by any sensor input other than
the Hold Open switch on TB2-1.
E3 Door length error Re-do First Installaon Sequence (FIS)
E4 Presence sensor monitoring failure Verify sensor wiring and safety logic seng
E5 Motor drive failure
F0 Inside monitored sensor failure Verify sensor wiring and safety logic seng
F1 Outside monitored sensor failure Verify sensor wiring and safety logic seng
F2 Upper Monitored Photo Beam failure Check transmier, receiver, and hold beam type
F3 Lower Monitored Photo Beam failure Check transmier, receiver, and hold beam type
F6 Inside (2) monitored sensor failure Verify sensor wiring and safety logic seng
F7 Outside (2) monitored sensor failure Verify sensor wiring and safety logic seng
ho Door held open Check sensors and hold beam type
FA Fire Alarm Acve
uL Unlocked delay egress
Table 4. Status Codes