10 ► HP210 User Manual
PREPARATION FOR USE
Do not operate HP210 until you have completed the
following steps:
READ THE ENGINE “OPERATING &
MAINTENANCE INSTRUCTIONS” MANUAL.
CHECK ENGINE CRANKCASE OIL LEVEL
Check the oil level before starting the engine. Make sure
the oil level is at the FULL MARK on the dipstick. Do not
overll. Use detergent oil classied "For Service SE, SF,
SG" as specied in the engine “Operating & Maintenance
Instructions” manual. See the “Operating & Maintenance
Instructions” manual for oil viscosity grade.
CHECK ENGINE FUEL LEVEL
If fuel level is low, ll with unleaded gasoline (85 octane
minimum).
CHECK HYDRAULIC FLUID
Ensure there is hydraulic uid in the hydraulic oil tank.
Below is a list of recommended oils.
Brand Biodegradable Description
CITGO No Hydurance AW32
AMS Oil No HVH 32
Exxon Mobil No Univis HVI26*
Exxon Mobil No DTE 10 Excel
Shell No S2 V 32
Chevron No Rando HDZ 32
Conoco Phillips No Unax AW-WR-32
Clarion (CITGO) Yes Green Bio 32
Exxon Mobil Yes EAL 224H
Chevron Yes Clarity AW32
Terresolve Yes Envirologic 132
Shell Yes Naturelle HF-E-32
*Recommended for extreme cold temperatures
INSTALL HYDRAULIC CONNECTIONS
STANLEY recommends you use hose lengths of 25 ft/8 m
with 1/2 inch/12.7 mm inside diameter. Hoses must have a
working pressure rating of at least 2500 psi/175 bar. Hose
ends must have male threads compatible with H.T.M.A.
quick disconnect ttings (NPT).
H.T.M.A. approved quick disconnect couplings are installed
to hydraulic hoses so that the direction of oil ow is always
from the male to the female coupling. Additional ttings,
such as reducers or adapter ttings, are not required.
If adapter ttings are used, they must be approved steel
hydraulic ttings meeting a minimum operating pressure
rating of 2500 psi/172 bar. Do not use galvanized pipe
ttings or black pipe ttings.
Use thread tape or pipe joint compound when installing
quick disconnect couplings to hose or tool ttings. Follow
the instructions furnished with the selected thread sealant.
DO NOT OVERTIGHTEN THE FITTINGS.
USING THE 12 VOLT DC OUTLET
A 12 VDC outlet is available for specic models. The DC
outlet is ON at all times.
Accessories left in the 12VDC outlet can drain the
battery if the HP210 is not running.
OPERATION