EasyManua.ls Logo

Stanley ProCare 8300A - Page 38

Stanley ProCare 8300A
38 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Stanley Access Technologies
65 Scott Swamp Road
Farmington, CT 06032
Document # 204144 REV B • www.stanleyaccess.com • 1.800.7.ACCESS
If the door:
HITS THE CLOSE STOP too hard
Set Close Check Length to 50. Set Close Press to 1 and test.
Increase the Close Brake seng unl there is good braking.
Increase or decrease Close Check unl there is smooth moon enter-
ing and in Close Check.
STALLS during opening without any
mechanical reason. . .
Connues to stall and it seems
to happen at the transion
from Open Brake to Open Check
Increase Obstruction Time from .5 seconds to 1.0 seconds
Make small increases to Open Brake.
STALLS during closing without any
obvious reason. . .
Connues to stall and it seems to
happen at the transion to Close
Check
Increase Obstruction Time
Increase Close Check one count at a me
SPEEDS UP during Close Check
Close Check Speed is set too high. Reduce Close Check one count at a
me unl door moon is suitable.
Attachment 7
Fine Tuning Slide Doors
(Sheet 2 of 2)
Tuning the Stanley Automatic Door (Continued).
Match your actual door to one from the list of doors described in the aachment. Start by installing these
sengs. Use the guide below to make adjustments to these sengs.