REV A 08STHT77404
S150
2
>3 sec
11
2
11
> 3
sec
≤ 3 sec
4 5
1
77404
1
3
Stanley Stud Sensor 150
The Stud Sensor 150 uses electronic signals to locate the edges of studs, joists
or live AC wires through drywall or other common building materials. Depth
detection selected by activation button for 1/2 inch, 1 inch and 1-1/2 inch. Once
the edge of a stud has been detected, the Stud Sensor 150 displays red LED’s
and sounds an audible tone. A marking channel allows you to easily note the
stud edges on the wall.
Note: Read all instructions prior to operating the Stud Sensor 150 and DO NOT
remove any labels from the tool.
WARNING:
Protect Your Eyes, Wear Safety Goggles.
Usage
Detecting Wood / Metal Studs
2
Hold the Stud Sensor 150 fl at against the surface,
making fi rm contact.
11
If the red LED stays lit, move the Stud Sensor 150
to a different location and try again. Releasing the
activation button will turn off the sensor.
Note: While calibrating, the Stud Sensor 150 must not
be placed directly over a stud, dense material such as
metal, or over a wet or newly painted area, or it will not
properly calibrate.
OPERATING INSTRUCTIONS
Battery
1
Open door on back of unit and connect a 9 volt battery
(not included) to clip. Put battery back into case and close
back battery door.
Note: Recommend to replace a new 9 volt battery
when low battery - fl ashing green LED.
Note: For best results the depth mode selected should be based on the
thickness of the surface material being scanned.
3
The green and top red LED will light.
Note: The unit cannot be moved before calibration is complete.
4
When the red LED goes off, the unit
is calibrated.
5
Keep holding the activation button
during all of the following procedures.
Note: Once the Activation button is
released, the unit shuts off.
• Marking Channel
• Live Wire Warning LED
• LED Display
• Activation Button
• Self-Calibration Complete /
Low Battery Indicator
• Depth Detection Mode
Selecting Scanner Depth Mode
3
• Depress and hold activation button once (1x) to
select to 1/2” read depth detection. The 1/2” mode
LED will illuminate.
• Double click (depress two times - 2x) and hold
activation to select to 1” read depth detection. The
1” mode LED will illuminate.
• Triple click (depress three times - 3x) and hold
activation button to select 1-1/2” read depth
detection. The 1-1/2” mode LED will illuminate.
• Live Wire Detected
• STUD Detected
Questo manuale d’istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per Stanley S150 o