EasyManuals Logo

Stanley TLM 130i User Manual

Stanley TLM 130i
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
12/146
10.2 Area
 Press key 7 once.
The area symbol appears on the display.
 Press key 4 and measure the first distance.
(e.g. length).
 Press key 4 and measure the second distance.
(e.g. width).
The device displays the result in the summary row
and the respective measured distance to the next
measurement in the second row.
10.3 Room volume
 Press key 7 twice.
The volume symbol appears on the display.
 Press key 4 and measure the first distance
(e.g. length).
 Press key 4 and measure the second distance
(e.g. width).
 Press key 4 and measure the third distance
(e.g. height).
The device displays the result in the summary row
and the respective measured distance to the next
measurement in the second row.
10.4 Pythagoras
 Press key 7 three times.
The Pythagoras symbol appears on the dis-
play.
 Press key 4 and measure the first distance
(diagonal measurement).
 Press key 4 and measure the second distance
(horizontal measurement).
The device displays the result in the summary row
and the respective measured distance to the next
measurement in the second row.
11 Troubleshooting
 If the message Error does not disappear after
switching on the device repeatedly, please
contact the dealer.
 If the message InFo appears with a number,
observe the instructions in the following table.
12 Technical data
No. Cause Correction
204 Calculation error Perform measurement
again.
252 Temperature too high Let the device cool
down.
253 Temperature too low Warm the device up.
255 Reception signal too
weak, measuring time
too long
Change target surface
(e.g. white paper).
256 Input signal too high Change target surface
(e.g. white paper).
257 Measuring error, too
much background light
Shadow the target
area.
258 Measurement outside
of the measuring range
Mind the range.
260 Laser beam interrupted Repeat the measure-
ment.
Range 0.1 m to 30 m
0.33 ft to 98 ft
Measuring accuracy (2 σ) typ.: ± 2.0 mm*
± 0.12 in*
Smallest unit displayed 1 mm
1/16 in
Laser class 2
Laser type 635 nm, < 1 mW
Automatic switch-off after 180 s
Continuous measuring yes
Addition/Subtraction yes
Dimension (H x D x W) 119 x 64 x 28 mm
4.67 x 2.52 x 1.10 in
Battery durability
(2 x AAA)
up to 3000 measure-
ments
Weight 100 g
Stanley TLM 130i.book Page 12 Tuesday, February 5, 2008 5:00 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stanley TLM 130i and is the answer not in the manual?

Stanley TLM 130i Specifications

General IconGeneral
BrandStanley
ModelTLM 130i
CategoryMeasuring Instruments
LanguageEnglish