16
Other Functions
■ Descaling function
Default time is 50 minutes, which is not adjustable
1. When the accumulated working time of heating pipe of evaporating heater
reaches 100 hours, the system will remind the user to remove the scale of
evaporating heater (user can also start the descaling function automatically).
At this moment, the descaling icon on the screen will flash.
2. The descaling mixture (water and clearing media) is prepared according to the
mixing ratio of 1:8 and then put into the water tank after an even mixing. The
dosage of descaling mixture in the water tank may not be lower than the
descaling scale of water tank.
3. After the descaling mixture or agent is added into the water tank and the oven
door is closed, press the SELECTION key to select the descaling function and
then press the ENTER key to start the descaling work.
4. The countdown mode is used for the product. When there are still 20 minutes,
the user is reminded to pull out the water tank to drain the descaling agent and
replace the clean water. After the water tank is inserted, the machine begins to
work. When there are still 10 minutes, the user is reminded again to pull out the
water tank to replace the clean water. After the water tank is inserted, the
machine begins to work. After the completion, the user will be prompted.
■ Setting Key function
Presetting time: During any program selection or standby mode, Press
Setting Key , it will start preset time setting, and Icon is on, the
Hour LED flashing (Preset time is 0-24 hours adjustable), after hour
confirmed, the Minute LED flashing, after minute confirmed, Interface
return to program selection mode, press key select program, after
Program selected, press the ENTER key to start this selected
program.
Presetting:
After presetting time starting, the preseted time interface and selected
program interface will display Alternately every 5 seconds;
,:,.
nn
•c·
uu
>.<
C>II