14
4. Temporarily set the toilet in place to check that there
is no piping interference. Remove the toilet and set it
aside.
5. Using a 2 step PVC gluing system, connect the
discharge piping and grinder/tank unit discharge fitting.
CAUTION: When applying glue to discharge fitting,
ensure that none gets into the check valve assembly,
which is built into the cover of the grinder/tank unit. Pay
close attention to the proper alignment of the discharge
fitting previously marked in STEP 1.
6. Using a 2 step PVC gluing system, connect vent piping
as required for proper venting.
PIPING
IL1748
IL1749
2-Step
PVC
Gluing
System
Check
Valve
Assembly
Discharge
Fitting
Pipe
IL1750
Vent
Pipe
Discharge
Pipe
4
5
6