1. Cut and dry-fit the pipe and fittings as required for
1" diameter discharge pipe (may be reduced to 3/4"
diameter if codes permit). While dry-fitting the discharge
pipe, position and mark the location of the grinder/tank
unit discharge fitting.
PIPING
2. Cut and dry-fit 1-1/2 in. vent pipe as required to
ensure that the vent pipe does not interfere with other
components. Make the connection to the grinder/tank
unit with the provided street elbow.
CAUTION: Proper venting is required for the toilet to
flush. Do not use a mechanical type vent.
3. A 2 in. x 1 in. 90° discharge fitting and a 1-1/2 in.
street elbow vent fitting have been provided for space
constraints in an exposed configuration. However, these
are not required for a hidden (behind a wall) installation.
On a hidden installation, simplify installation and
improve performance by replacing the 90° discharge
fitting with a straight discharge pipe instead. Use a 2 in.
straight coupling and reduce it down to 1 in.