Steam generator
Water Drain Valve
Water Inlet Pipe
Steam outlet pipe
Control panel
Supply
Steam Outlet
Pressure
relief
valve
!
The steam generator( including the controller)
comply with CE , CSA
and
UL certificat ion standards.
!
Attention:
Attention:
Installation drawing of the steam generator
The drawing is only
for sample. As for practical
design of steam room, please
consult with qualified designer,
architect or builder.
User Manual
Control Cable
(20ft max)
7. The steam generator should be securely mounted. Make adequate care that the generator
is stable and level, horizontally. The steam generator has hanging holes in the back side for
mounting onto a wall.
8. The steam generator requires a minimum of 12 inch clearance of space on both sides, top and front.
9. The steam generator must be installed in a place that is easily accessible, and convenient for removal,
or disassembly.
10. The installation area must have access to a drain.
11. The steam line(s), pressure relief valve, drain valves, water supply line, and steam outlets
are VERY HOT during and after use for some time. Keep the steam outlets away from any
body parts or bathers. Bodily injury or burn may occur if coming into contact or in the visinity
of the steam nozzles. Provide appropriate protection to avoid bodily injury.
(10.5 kw and higher require 2 steam outlets)
Intake or Drain Valves 2