_________________________________________________________________________________
TOLO SAUNA info@tolosauna.com www.tolosauna.com
i. Water Inlet:
First connect the water magnetizer (if applicable) to the water inlet solenoid valve. Then please
use a 1/2’’ flexible stainless steel hose to connect the other side of the water magnetizer and the
water supply pipeline. Do not connect to metal water supply pipeline directly which may damage
the water inlet valve.
Attention: Only use cold water supply.
ii. Drain Outlet
Please use 3/4’’ copper pipe or stainless steel pipe to connect the drain outlet and the drain
pipeline of the house. The drain pipeline should be installed with small angle so as to help
residual water in the steam generator flow to the drain pipe.
Attention: Don’t use locking pliers to over tight the drain pipe connection. Just make sure it
without leakage under Teflon tape sealing. The water come out from the steam generator will
over 100℃. Don’t use the plastic pipe/acrylic pipe/FRP pipe or other similar material pipe.
iii. Steam outlet
Please use copper or stainless steel pipe to connect the steam head and the steam outlet pipe of
the generator. The pipe should be less than 3 meters long and minimize the number of elbows,
otherwise heat isolating methods should be implemented.
For 3KW-6KW steam generator, steam outlet is 1/2’’, please AT LEAST use 1/2’’ steam pipe,
must be stainless steel pipe or copper pipe.
For 7KW-13.5KW steam generator, steam outlet is 3/4’’, please AT LEAST use 3/4’’ steam pipe,
must be stainless steel pipe or copper pipe.
For 15KW-24KW steam generator, steam outlets are TWO 3/4’’ , please AT LEAST use TWO
SEPARATE 3/4’’ steam pipes, don’t cross the two steam pipes, must be stainless steel pipe or
copper pipe.
Attention: Please MUST choose right diameter steam pipe, as if the pipe size is smaller than
our instruction, it may cause the steam generator internal pressure to increase suddenly which
may damage the steam generator and have safety risk.
iv. Safety Valve
It’s to release the pressure of steam generator, use 1/2’’ copper pipe or stainless steel pipe to
connect the safety valve and the drain pipeline of the house. Please don’t block it.
v. Steam Head
The steam head should be about 300mm from the ground and at least 150mm from customer
seats. Please apply silicone glue on the steam pipe nipple and back of the steam head, and then
screw the steam head on to the steam pipe nipple. Please refer to figure 13, the Aromatherapy
reservoir should face upwards.