EasyManua.ls Logo

Steamtec AIO - User Manual

Steamtec AIO
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
_________________________________________________________________________________
TOLO SAUNA info@tolosauna.com www.tolosauna.com
1
Steamtec AIO
Steam Generator Manual
DO NOT use locking pliers to over tight the
DRAIN PIPE connection
Please read the manual carefully before installation
and keep the manual for further reference

Questions and Answers

  • K
    Kevin FisherAug 1, 2025
    Why does my Steamtec AIO keep heating up?
    • V
      vreyesAug 1, 2025
      If your Steamtec Iron continues heating even when the temperature is more than 2°C above the set value, carefully test the relays on the sub-board and replace any faulty ones. Alternatively, replace the entire sub-board.
  • E
    Elizabeth WhiteAug 6, 2025
    How to fix a Steamtec AIO that fills water but doesn't heat?
    • B
      Brooke ValdezAug 6, 2025
      If your Steamtec Iron fills and drains water correctly but isn't heating up, check the connection wire between the main circuit board and the sub-board, the relays on the sub-board, and the heating elements.
  • P
    Paul NguyenAug 10, 2025
    What to do if Steamtec AIO overheats?
    • M
      Monica RushAug 10, 2025
      If the inner tank temperature of your Steamtec Iron exceeds 115°C, immediately disconnect the power supply. After the steam generator has completely cooled down, carefully inspect the heating elements, water level sensor, relay on the sub-board, and the water supply pipeline. The temperature switch can only be manually reset after the fault has been located and resolved.
  • I
    Isabel MahoneyAug 14, 2025
    How to troubleshoot communication fault in Steamtec Iron?
    • N
      nelsonmistyAug 14, 2025
      If there's a communication fault between the controller and circuit board on the central box of your Steamtec Iron, check the connection cable for any turn offs or short offs, and verify the wire connections.
  • G
    gpotterAug 18, 2025
    What to do if Steamtec Iron leaks water from steam outlet?
    • S
      Sharon AustinAug 18, 2025
      If water is heavily coming out from the steam outlet pipe of your Steamtec Iron, clean or replace the outlet solenoid valve.
  • D
    davisjenniferAug 22, 2025
    What to do if Steamtec AIO sensor reads over 60 °C?
    • T
      Travis StephensAug 22, 2025
      If the temperature measured by the temperature sensor in your Steamtec Iron is above 60°C, verify whether the room temperature is above 60°C. The code should disappear once the room temperature drops below 60°C. Otherwise, check the sensor connection.
  • A
    Anthony MasonAug 27, 2025
    What to do if Steamtec AIO Iron sensor reads below 6 °C?
    • M
      maria20Aug 27, 2025
      If the temperature measured by the temperature sensor in your Steamtec Iron is below 6°C, check if the room temperature is below 6°C. The code should disappear once the room temperature reaches 6°C. Otherwise, check the connection of the sensor.

Summary

Safety Warning

Install Cautions

Parameters

Models, parameters and dimension

Details product models, technical specifications, and physical dimensions.

Installation And Cautions

Installation cautions

Provides essential warnings and precautions for installation.

Installation of steam generator body

Guides on mounting the main unit. Includes cautions and installation steps.

Installation of Central function box

Instructions for installing the central function box.

Installation of controller and temperature sensor

Cautions

Safety warnings regarding wire placement for controller and sensor.

Installation of controller

Step-by-step guide for mounting the control unit.

Installation of temperature sensor

Instructions for installing the temperature sensor in the steam room.

Installation of pipeline

Water Inlet

Instructions for connecting the water supply to the unit.

Drain Outlet

Guidelines for connecting the drain pipe for water discharge.

Steam outlet

Instructions for connecting the steam outlet pipe for steam delivery.

Installation of electrical circuits

Cautions

Critical safety warnings for electrical circuit installation.

Power Supply

Details on connecting the main power supply to the generator.

Wire Diagram

Visual representation of the electrical wiring connections.

Functions And Operation

Maintenance

Replace the heating elements

Step-by-step guide for replacing heating elements.

Replace the main board

Instructions for replacing the main circuit board.

Replace the sub-board

Guide for replacing the sub-board components.

Replace the solenoid water inlet valve

Procedure for replacing the water inlet solenoid valve.

Replace the water level sensor

Instructions for replacing the water level sensor.

Troubleshooting

-L Temperature below 6°C

Troubleshooting for low temperature readings.

-H Temperature higher than 60°C

Troubleshooting for high temperature readings.

-E Water supply or fill faults

Diagnosing issues with water supply or filling.

EE Communication fault

Troubleshooting communication errors between controller and box.

Diagnosing procedure

Steps to diagnose and resolve common generator issues.

Steamtec AIO Specifications

General IconGeneral
BrandSteamtec
ModelAIO
CategoryIron
LanguageEnglish