EasyManua.ls Logo

Steiel EF110 pH - Packing List; Technical Data; Principle of Operations

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EF110_r1.0 – 10/2019 p. 15
PACKING LIST
The EF110 pump is supplied complete with:
- Bracket for wall installation
- Standard kit including suction and head tube, foot filter and injection valve
- Power cable, 1.5 m (internally pre-wired)
- Instruction manual
TECHNICAL DATA
Flow rate / Pressure 1.8 l/h @ 1 bar, other versions upon request (0.6, 1.2, 2.4 l/h @ 1 bar)
Suction / Delivery Hoses 4x6 mm, PVC Crystal
Materials Case: PP
Front: Lexan control panel,
polycarbonate transparent protection
Roller-holder: PBT
Rollers: Delrin (self-lubricant)
Internal tube: Santoprene (or silicone)
Connections: PP
Environment Working temperature max 45°C
Storage temperature max 60°C
RH max 90% noncondensing
Protection Rate IP54
Dimensions 100 x 160 x 135 mm
Weight approx. 2 kg
Power Supply 230 V~, 50 Hz, single phase
Power Consumption max 10 VA
Electrical Protection Fuse 1 A (@ 230 V~), 5x20 mm
Display LED, 3 digit
Level Input on proper connector, accept ohmic contact from level sensor,
5 V / 5 mA
pH / ORP input on BNC connector, input impedance greater than 10^12 Ω,
precision better than 1% FS, repeatability better than 0.2% FS
Measure Ranges 0.00 to 14.00 pH; 0 to +1000 mV (ORP)
PRINCIPLE OF OPERATIONS
The principle of operation of the peristaltic pumps is based on the pressure and subsequent release of the
internal tube by the roller mounted on the roller-holder, which is driven by the motor. The dual action of
pressure and release of the tube generates a suction force along the tube itself which primes the liquid
and guide it to the injection line.
The command is sent to the motor by the electronic unit according to the program, to the detected
measurement and to the absence of alarms / errors.
These pumps are also equipped with a built-in instrument, that detects and manages pH and redox
measurements.