EasyManua.ls Logo

stellar labs 7621 - Page 40

Default Icon
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 36 | Stellar
®
Heavy-Duty Telescopic Crane Owner’s Manual
Maintenance Procedures
Stellar Industries recommends the rst lter change to occur after the rst 250 hours of service.
The second, and every subsequent change, should occur after every 1,000 hours of service. By
following these guidelines, the hydraulic oil should last up to 6,500 hours.
Note: These recommendations are based on normal working parameters. If operating in less than
favorable conditions excessive dust, moisture, etc.), be sure to check the lter gauge often for lter
change notice.
Hydraulic Oil/Filter Maintenance
Important: Prior to washing the Stellar crane, all electrical components must be covered to prevent
any water from being injected into the plastic housing. Avoid any direct water pressure to any of
the electrical components.
Washing the Crane
Touch up any chips or scratches to prevent further paint damage.
Paint Maintenance
Every six (6) months, remove the hydraulic pump from the PTO and lubricate the splines using Stellar
PN 20885. Failure to lubricate shaft splines will cause damage to the PTO and Hydraulic pump.
PTO and Pump Maintenance
Proper maintenance is key in ensuring a long lasting rope. Refer to ANSI B30.5 for details on
maintaining your wire rope.
Wire Rope Maintenance
Courtesy of CraneMarket.com