Model | ECON FP E20PHH |
---|---|
Category | Water Pump |
Pump Type | Peristaltic |
Voltage | 120V |
Power Supply | AC |
Housing Material | Polypropylene |
Diaphragm Material | Santoprene |
Maximum Flow Rate | 20 gpd |
Details the warranty period, coverage, and exclusions for Stenner pumps.
Emphasizes the importance of reading and adhering to all provided instructions.
Crucial safety instruction for electrical connection, requiring GFCI protection.
Safety directive to replace any damaged power cords promptly to prevent shock hazards.
Highlights specific hazards related to electric shock.
Critical safety instruction to disconnect power before accessing internal components.
Warning that the pump is not designed for use in explosive environments.
Step 1: Calculate the available dose time in seconds based on flow rate.
Step 4: Program the operating mode and time percentage.
Step 2: Calculate the pump's operating time in seconds.
Instructions to unlock the control panel keypad.
Warning about potential dosing errors if pump operating time exceeds available dose time.
Instructions for setting the pump's operating time percentage.
Step 3: Calculate the required pump speed percentage.
Step 2: Calculate the chemical feed duration in seconds.
Step 4: Program the operating mode and speed percentage.
Warning about flow rate exceeding calculated values, leading to reduced feed duration and errors.
Step 1: Calculate the pump speed percentage setting.
Step 2: Program the operating mode and speed percentage.
Instructions for setting the pump's operating mode.
Steps to take the pump out of standby and prime it.
Crucial instruction to avoid mounting the pump vertically with the head upwards to prevent damage from leaks.
Warning against mixing additives directly in the container and to follow manufacturer instructions.
Warning and instruction to shut off systems and bleed pressure before working with hazardous pressure.
Prohibition of thread sealant tape and tools for pump tube connections.
Warning against sliding tubing to the strainer's bottom, which can cause priming issues.
Critical safety warning regarding hazardous voltage and disconnecting power.
Crucial reminder to unplug the pump before any maintenance.
Procedure to unlock the control panel keypad.
Prohibition of greasing pump tubes or housing.
Warning against pulling excessively on the pump tube during installation.
Caution when disconnecting discharge line, as it may contain pressurized fluid or chemicals.