The pump is controlled with 6 buttons. The chart indicates the function of each button on the
c
ontrol panel.
BUTTON GENERAL FUNCTION OPERATING MODE FUNCTION
• Moves up in a menu
I
ncreases the speed percent
UP Toggles between menu options
in the MANUAL mode
• Increases a value
• Moves down in a menu
Decreases the speed percent
D
OWN Toggles between options
i
n the MANUAL mode
• Decreases a value
Runs pump at 100% speed
P
RIME N/A
w
hile button is pressed
Turns pump control ON or OFF
O
N/OFF N/A
WARNING: DOES NOT remove power
M
oves one step back in a menu
C
ycles the display through
BACK
when permitted
the units of output and
the control mode specific parameters
E
NTER Sets a value
Press and hold for 2 seconds
to go to the MAIN MENU
25 psi (1.7 bar) maximum
Item Number Pump Turndown Gallons Gallons Ounces Ounces Liters Liters Milliliters Milliliters
Prefix Tube Ratio per Day per Hour per Hour per Minute per Day per Hour per Hour per Minute
S3003 3 100:1 0.40–40.0 0.017–1.67 2.13–213.0 0.036–3.56 1.51–151.0 0.063–6.31 63.09–6309.0 1.05–105.0
S3004 4 100:1 0.60–60.0 0.025–2.50 3.20–320.0 0.053–5.33 2.27–227.0 0.095–9.46 94.64–9464.0 1.58–158.0
S3005 5 100:1 0.85–85.0 0.035–3.54 4.53–453.0 0.076–7.56 3.22–322.0 0.134–13.41 134.07–13407.0 2.23–223.0
NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment. Many
variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
Approximate Outputs @ 50/60Hz
100 psi (6.9 bar) maximum
Item Number Pump Turndown Gallons Gallons Ounces Ounces Liters Liters Milliliters Milliliters
Prefix Tube Ratio per Day per Hour per Hour per Minute per Day per Hour per Hour per Minute
S3001 1 100:1 0.05–5.0 0.0020.21 0.2727.0 0.004–0.44 0.19–19.0 0.0080.79 7.89–789.0 0.1313.0
S3002 2 100:1 0.17–17.0 0.007–0.71 0.91–91.0 0.015–1.51 0.64–64.0 0.027–2.68 26.81–2681.0 0.45–45.0
S3007 7 100:1 0.40–40.0 0.017–1.67 2.13–213.0 0.036–3.56 1.51–151.0 0.063–6.31 63.09–6309.0 1.05–105.0
Approximate Outputs @ 50/60Hz
25 psi (1.7 bar) maximum
Item Number Pump Turndown Gallons Gallons Ounces Ounces Liters Liters Milliliters Milliliters
Prefix Tube Ratio per Day per Hour per Hour per Minute per Day per Hour per Hour per Minute
S405X 5X 100:1 1.5–150.0 0.06–6.25 8.0–800.0 0.13-13.33 5.7–567.0 0.24–23.66 236.59–23659.0 3.94–394.0
Approximate Outputs @ 50/60Hz
100 psi (6.9 bar) maximum
Item Number Pump Turndown Gallons Gallons Ounces Ounces Liters Liters Milliliters Milliliters
Prefix Tube Ratio per Day per Hour per Hour per Minute per Day per Hour per Hour per Minute
S407X 7X 100:1 0.6–60.0 0.03–2.50 3.2–320.0 0.053–5.34 2.3–227.0 0.09–9.46 94.64–9464.0 1.58–158.0
Approximate Outputs @ 50/60Hz
MA I N M E NU
-
CO N F I GU R AT IO N
-
CO N T R O L MO D E
-
RU N P UM P
C
ONTROL PANEL
FLOW RATE OUTPUTS
INSSQS 080119a
1
Mandatory Calibration
From the Configuration menu, select GPD/LPD Calibration, and enter your
pump's ACTUAL maximum flow rate output. Refer to illustration below.
Enter max pump flow
__0.0 GPD
C
alibration
-
GPD/LPD Calibration
-
Signal Calibration
-
GO TO CONFIG MENU
C
onfiguration
-
Units
-
Clock
-
Calibration
adjust
set
2
Program Applicable Pump Parameters
In Configuration menu, program applicable pump parameters, refer to chart below.
3
Select Mode of Operation
In Control Modes menu, select your mode of operation.
4
Program the Options
In your selected control mode, program the options relevant to your application.
5
Run the Pump
Pump Parameters Description Control Mode
Display Brightness Optimal setting is < 50% for extended periods. All
Units Default is Gallons; enter Liters, if preferred. All
Clock 24-hr format. Enter current time of day and day of the week. All
Leak Detect Calibrate sensitivity to distinguish between water & your chemical. All
Tube Timer Enter number of hours you want pump to run before display All
shows TUBE CHANGE.
Password Program a password to prevent unauthorized changes to pump settings. All
Relay Outputs Three individual relays available; rated for 24VDC @ 50mA max. All
Program communication for:
• S Series to back-up S Series
• S Series to another device
Signal Calibration If factory settings are not sufficient, calibrate the pump using a 4-20mA, 0-10VDC
process meter or powered transmitter.
Reset Totalizer Option to reset the total tallied amount of water treated. Pulse, Hall Effect, PPM
S Series Manual
·
www.stenner.com or
S SERIES PUMP S30 Models
ACCESSORIES
3
Connecting nuts 1/4" or 3/8"
3 Ferrules 1/4" or 6 mm Europe
1
Injection fitting 25 psi (1.7 bar) max.
or Injection check valve 100 psi (6.9 bar) max.
1 Weighted suction line strainer 1/4", 3/8" or 6 mm Europe
1 20' Roll suction/discharge tubing
1/4" or 3/8", white, UV black or 6 mm white Europe
1
Additional pump tube
2 Additional latches
1
Mounting bracket
1 Quick Start Guide
Download complete S Series Manual www.stenner.com
S SERIES PUMP S40 Models
3 Connecting nuts 3/8"
1 Injection ball check valve
1 Weighted suction line strainer 3/8"
1 20' Roll suction/discharge tubing 3/8", white or UV black
1 Additional pump tube
1 Mounting bracket
1 Quick Start Guide
Download complete S Series Manual www.stenner.com
TO BE INSTALLED AND MAINTAINED BY PROPERLY TRAINED PROFESSIONAL INSTALLER ONLY. READ MANUAL &
L
ABELS FOR ALL SAFETY INFORMATION & INSTRUCTIONS.
W
arns about hazards that CAN cause death, serious personal injury, or property damage if ignored.
ELECTRIC SHOCK HAZARD
RISK OF ELECTRIC SHOCK
Connect only to a branch circuit protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify
that the receptacle is protected by a GFCI.
RISQUE DE CHOC ELECTRIQUE
Brancher seulement à un réseau électrique protégé par un DDFT. Contactez un électricien certifié si vous ne pouvez pas vérifier que la
p
rise est protégé par un DDFT.
PELIGRO DE DESCARGA ELECTRICA
Conecte a un circuito en derivación protegido por un interruptor de descarga a tierra (GFCI). Contacte a un electricista certificado si no
p
uede verificar que su receptáculo esté protegido por dicho interruptor (GFCI).
T
o reduce the risk of electric shock, replace damaged cord immediately. Contact the factory or an authorized service facility
for repair.
DO NOT alter the power cord or plug end. DO NOT use receptacle adapters.
DO NOT use pump with a damaged or altered power cord or plug. Contact the factory or authorized service facility
f
or repair.
After installation, the power supply plug must be accessible during use.
To reduce the risk of injury, do not permit children to use this product. This appliance is not to be used by persons with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
This pump has not been investigated for use in marine areas.
La pompe n’a pas été vérifiée et approuvée pour utilisation sur des applications de installation marine.
Este dosificador no ha sido investigado para uso en áreas marinas.
EXPLOSION HAZARD
This equipment IS NOT explosion proof. DO NOT install in an explosive environment.
RISK OF CHEMICAL EXPOSURE AND OVERDOSE
Potential for chemical burns, fire, explosion, personal injury, or property damage. To reduce risk of exposure, the use of proper personal
protective equipment is mandatory. To reduce risk of overdosing, follow proper installation methods and recommendations. Check your
local codes for additional guidelines.
RISK OF FIRE HAZARD
DO NOT install or operate on any flammable surface.
Pump is not recommended for installation in areas where leakage can cause personal injury or property damage.
P
ELIGRO
Warns about hazards that WILL or CAN cause minor personal injury or property damage if ignored.
To reduce risk of electric shock, pull plug before servicing this pump.
This pump has been evaluated for use with water only.
Non-submersible pump. Suitable for indoor and outdoor use.
Pompe non submersible. Adaptée à une utilisation aussi bien à l’intérieur qu’à l’extérieur.
Dosificador no sumergible. Adecuado para el uso interior y exterior.
PLUMBING
Chemical feed pump installation must always adhere to your local plumbing codes and requirements. Be sure installation does not
constitute a cross connection. Check local plumbing codes for guidelines.
Electrical installation should adhere to all national and local codes. Consult licensed professional for assistance with proper
electrical installation.
Pump uses a class 2 switching power supply.
SAVE THESE INSTRUCTIONS
NOTICE: Indicates special instructions or general mandatory action.
This metering pump is portable and designed to be removable from the plumbing system without damage to the connections.
This metering pump and its components have been tested for use with the following chemicals; Sodium Hypochlorite (10-15%),
Muriatic Acid (20-22 Baume, 31.5% Hcl), and Soda Ash.
Cette a pompe de dosage et ses composants ont été testés pour utilisation avec les produits chimiques suivants; Hypochlorite de Sodium
(solution de 10-15%); Acide Muriatique (20-22 Baume, 31.5% Hcl); Cendre de Soude.
Before installing or servicing the pump, read the pump manual for all safety information and complete instructions. The pump is designed
for installation and service by properly trained personnel.
No user replaceable parts inside.
Do not install at altitudes over 2000 meters.
Read all safety hazards before installing or servicing the pump. The pump is designed for installation and service by properly trained personnel.
Use all required personal protective equipment when working on or near a chemical metering pump.
Install the pump so that it is in compliance with all national and local plumbing and electrical codes.
Use the proper product to treat potable water systems, use only chemicals listed or approved for use.
Inspect tube frequently for leakage, deterioration, or wear. Schedule a regular pump tube maintenance change to prevent chemical
damage to pump and/or spillage.
Recommended mounting is vertical with pump head pointed downward.
CAUTION
CAUTION
CAUTION
ATTENTION
CUIDADO
CAUTION
CAUTION
CAUTION
CAUTION
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
W
ARNING
WARNING
PELIGRO
WARNING
W
ARNING
WARNING
WARNING
S SERIES PERISTALTIC METERING PUMP
For assistance, contact techsupport@stenner.com or 904.641.1666 or 800.683.2378.
GENERAL INFORMATION QUICK START GUIDE
IMPORTANT!
The pump’s ACTUAL maximum flow rate entry:
Affects flow rate output displayed on the screen during operation in all modes.
Contributes to overall calculation of flow rate output in the PPM modes.
IMPORTANT! The Quick Start Guide is a summarized overview for the initial set-up.
Refer to the S Series Manual for wiring & programming required for your specific application.
ACCESSORIES
FLOW RATE OUTPUTS

Other manuals for Stenner Pumps S Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stenner Pumps S Series and is the answer not in the manual?

Stenner Pumps S Series Specifications

General IconGeneral
BrandStenner Pumps
ModelS Series
CategoryWater Pump
LanguageEnglish

Related product manuals