14
Program Distribution
Program Distribution requires one
extra pair of wires in the installation
cable. A program source is connected
to this dedicated wire.
ACTIVATE PROGRAM
DISTRIBUTION
• Dial code 96 from any master station.
• The program is put on hold during
incoming and outgoing calls
- the program is automatically
reconnected when the call is termi-
nated.
• Press the X-key to cancel the
Program Distribution feature.
Remote Program
Distribution
Program Distribution requires one
extra pair of wires in the installation
cable. A program source is connected
to this dedicated wire.
Master stations can connect Program
Distribution to other stations, e.g.
substations without any key-pad.
TRANSFER PROGRAM
DISTRIBUTION
• Dial 98 + substation no. + sound
level 1-3 from any master station.
• The program is put on hold during
incoming and outgoing calls in the
substation
- the program is automatically
reconnected when the call is termi-
nated.
TERMINATE TRANSFERRED
PROGRAM DISTRIBUTION
• Dial 98 + substation no. + 0 from
any master station
NOTE:
By dialling 98 + 0 from the master
station, all receivers of Program
Distribution will be disconnected.