16
5. System Flush. (optional) Flushing solvent is pumped through the pump, spray bar, and
wand to clean material from the system.
WARNING: The burners must be extinguished prior to performing flushing operations. DO
NOT allow flushing solvent to contaminate the contents of the main tank.
a. Disengage pump.
b. Set the Recirculate/Spray valve to "Spray" position.
c. Set the Product/Flush valve to "Flush" position.
d. Set the Wand/Spray Bar valve as needed to flush the system as desired.
e. Place a suitable container under spray bar.
f. Engage pump in “Forward” position to flush system.
g. Open valve on wand handle to flush wand.
h. When complete, disengage pump.
i. Dispose of flushing solvent in accordance with local, state, and federal laws.