61
Step 28: Repeat steps 26 and 27 for display values of 4 through 2, changing each parameter to
nonE.
Note: The upper display will show the previous value you changed. You must increment this value from 4 through 20!
Step 29: When all 20 parameters are set, press the infinity key once to return you to the main
Factory Page, CUSt will be in the upper display and FCty will be in the lower display.
Step 30: Use the up or down keys to move to the Lockout submenu. LoC will be in the upper
display and FCty will be in the lower display. Press the advance key to enter the Lock
out submenu.
Parameter Value Description
(use the up or down keys to change parameter values)
30-1 LoC.o 2 Lock Operations Page
Advance key
30-2 rLoC 1 Read Lockout Security
Advance key
30-3 SLoC 1 Set Lockout Security
Advance key
Step 31: Pressing the advance key at parameter SLoC will advance you to back to parameter
LoC.o. Press the infinity key to return you to the Lockout submenu.
Step 32: Press the infinity key again to return you to the Home page.
Congratulations! Programming is Complete.