4 Operating Instructions
69
10432589_G AMSCO® 7000 Series
Operator Manual
2. For manual unloading of washer/disinfector (without ATLAS Workflow Automation Vehicle or SCS conveyor on
unload side), proceed as follows:
a. Bring a transfer cart next to washer/disinfector unload door and ensure transfer cart brakes are applied
(FD61-700 or FD199 for 7052HP W/D and FD179 for 7053HP W/D):
Ensure appropriate transfer cart wheels are locked and swiveling is not possible;
Ensure transfer cart is at the proper height.
b. Carefully pull accessory rack onto transfer cart.
c. Press Close Door to close unload door.
Washer/Disinfector Equipped with a SCS Conveyor System
For automatic unloading with the ATLAS Workflow Automation Vehicle, proceed to Step 4.
3. For automatic unloading with SCS Conveyor System, proceed as follows:
a. Bring a transfer cart next to feed-out conveyor and ensure transfer cart brakes are applied. Ensure
appropriate transfer cart wheels are locked and swiveling is not possible.
b. If feed-out conveyor is already full, display shows message:
Unload conveyor not ready
or:
If feed-out conveyor is ready, accessory rack is indexed onto feed-out conveyor.
c. Once SCS conveyor has completed unloading process, washer/disinfector unload door closes.
d. Cycle complete screen is displayed and washer/disinfector is ready for next cycle.
Washer/Disinfector Equipped with an ATLAS Workflow Automation Vehicle
4. The Automatic pickup request at a washer is always automatic as soon as the washer Automatic mode is
activated.
The rack is picked up by the ATLAS Workflow Automation Vehicle if one of the Operator workstation called for
this type of rack, or if an ATLAS WAV Rack Workstation is available.
For details about operation of the ATLAS Workflow Automation Vehicle and about pickup requests, refer to the
ATLAS WAV System Operator Manual (10370540).
4.7 Visual Inspection
IMPORTANT: Good Hospital Practice dictates all instruments be inspected for visible debris after processing in the AMSCO
7052HP Single-Chamber Washer/Disinfector or in the AMSCO 7053HP Single-Chamber Washer/Disinfector. Any instrument
with visible debris must be rewashed until clean and free of visible debris prior to terminal processing. Failure to reprocess until
all visible debris have been removed may impede terminal processing.
1. Once items are cool, check for any residue or soil.
2. Any item that has not been cleaned properly must be reprocessed.
4.8 Responding to an Alarm
Alarm messages warn the operator that the washer/disinfector is experiencing an abnormal condition. Alarm conditions
can be caused by failure of utility supplies or by washer/disinfector components.
Refer to Section 7.1, Troubleshooting Introduction for a detailed listing of alarms.
NOTE: Some alarm conditions can be resolved by the operator.
1. When a malfunction or an alarm occurs before cycle is successfully completed, an alarm sounds and display
shows: