EasyManua.ls Logo

Sterling Power BB1230 - Front Panel Display II; Under the Lid Connections; Physical Dimensions; Cables and Fuses Guidelines

Default Icon
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Models: BB1230 | BB122430 |
BB242435 | BB244860
MODELS:
BB1260 / BB122470 / BB123670
BB124870 / BB241235
Front Panel II (under red end cap)
4.60
7
3
.
0
0
4.60
158.00
1
9
8
.
5
1
4
3
.
1
3
158.00
5
.50
1
0
.
6
0
4
.
6
0
1
1
2
.
1
3
4
.
0
0
199mm(H)
158mm(W)
70mm(D)
50mm(D)
units in millimetres (mm)
Under the lid
1) N/A
2) Negative fuse (position, model dependent).
3) DC output to auxiliary battery.
4) Common negative.
5) DC input from start battery (green connector or brass
nut / bolt - model dependent).
6) N/A
7) Remote control socket.
8) BMS 1 - 0V signal from BMS shall trip BB.
9) BMS 2 - positive signal (+ve) from BMS shall trip BB.
10) Ignition feed connector (on) Euro 6 engines.
11) Remote battery sense wire to compensate for voltage
drop in cable (optional, does not need to be used).
12) Battery temperature sensor, optional fit, if not used
product will work on default at 20 deg C setting. Polarity
does not matter when connecting.
13) Other wire associated with the temp sensor, as per 12.
Dimensions
5
Aux
Bat
out +
Engine
Batt.
input +
Solar Neg
Max V
31V
Com.
Neg.
BMS 2 (5)
BMS 1 (6)
Battery temp.
sensor (1,2)
Ignition
feed (4)
Remote
Voltage
sense (3)
Upper
Lower
Remote
control
Solar
Pos+
+ + +
- -
1 2 3
4 5 6
Output To
Aux Batt
111213
10 8 9
3415 165
7
15) Solar positive input from 12V solar panel (up to 31V)
16) Solar negative input from 12V solar panel (up to 31V)
Models:
BBS1230
This chart is a guideline based on the
typical lengths of cable that shall run
to and from the BB. Please only use
this chart as a guide. If you wish to
make the cable longer than typical,
then you would generally use thicker
cable. We recommend rating the
fuse based on cable thickness. Rate
the cable based on the current going
down the cable and the length of the
run.
input cable output cable
Model (mm2) / AWG (mm2) / AWG input fuse output fuse
BB1230 10mm2 / 8 10mm2 / 8 40A 40A
BBS1230 10mm2 / 8 10mm2 / 8 40A 40A
BB122430 10mm2 / 8 6mm2 / 10 40A 30A
BB242435 10mm2 / 8 10mm2 / 8 40A 40A
BB244830 10mm2 / 8 4mm2 / 12 40A 20A
BB1260 16mm2 / 6 16mm2 / 6 80A 80A
BB122470 16mm2 / 6 10mm2 / 8 80A 40A
BB123670 16mm2 / 6 6mm2 / 10 80A 30A
BB124870 16mm2 / 6 4mm2 / 12 80A 20A
BB241235 10mm2 / 8 16mm2 / 6 40A 80A
Cables and fuses (guideline only)
2
f u s e
Aux
Batt
out +
Engine
Batt.
input +
Com.
Neg.
BMS 2 (5)
BMS 1 (6)
Battery temp.
sensor (1,2)
Ignition
feed (4)
Upper
Lower
Remote
control
+ +
-
1 2 3
4 5 6
111213
10 8 9
345
7
2
f u s e
SETUP
SELECT
Aux
Batt
out +
Engine
Batt.
input +
Com.
Neg.
BMS 2 (5)
BMS 1 (6)
Battery temp.
sensor (1,2)
Ignition
feed (4)
Remote
Voltage
sense (3)
Upper
Lower
Remote
control
+
-
1 2 3
4 5 6
111213
10 89
34
5
7
2
f u s e
+

Related product manuals