20 | ACCELERA 300 WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
INSTALLATION
1.
2.
3.
26_03_01_1387
» Keep the water heaters slightly tilted.
» Wind out the free leveling foot, but not by more
than 1.1" (30 mm).
» Turn the locking nut on the thread of the leveling
foot towards the bottom cover. When the locking
nut is tight against the bottom cover, it stabilizes
the leveling foot.
26_03_01_1384
» Push two polystyrene
®
installation aids with the
step-shaped corner underneath the water heater.
The water heater is subsequently set and tilted onto
this profile. Ensure that you do not set the water
heater down in the area of the joint edge of the
sheet steel jacket, but at least 6" (150 mm) along.
26_03_01_1388
» Tilt the water heater that has been set down on the
polystyrene
®
installation aids.
» Remove the remaining floor semi-shell.
» In the tilted state of the water heater, wind out the
second and third leveling foot, but not by more than
1.1" (30 mm).
» In both cases, tighten the locking nut against the
bottom cover.
» Position the water heater on the three leveling feet.
» Level the water heater vertically by adjusting the
three leveling feet.
» Remove any packaging that remains on the water
heater.
» Install condensate drain elbow.
This is the best time to install the condensate
drain elbow.